2011
DOI: 10.1002/cite.201100014
|View full text |Cite
|
Sign up to set email alerts
|

Droplet Cluster – Analysis, Simulation and Visualization

Abstract: Droplet Cluster -Analysis, Simulation and VisualizationOptical measurements are performed with an inline measurement technique in laboratory and pilot plant columns to obtain information about the droplet swarm at specific locations as a function of process parameters, e.g., time, energy input, and throughput. The column simulation tool LLECMOD was extended to packed and pulsed columns with the possibility of a free choice of the dispersed phase and mass transfer direction. The CFD simulation provides the basi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0
4

Year Published

2013
2013
2019
2019

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 17 publications
(18 citation statements)
references
References 42 publications
0
14
0
4
Order By: Relevance
“…The right part contains an area camera (CCD) equipped with a telecentric lens. The OMOP performed well in previous works with different types of apparatuses [19,24,25,27]. The telecentric principle enables a distance-independent imaging of the actual particle sizes without distortion effects.…”
Section: Modified Optical Multimode Online Probementioning
confidence: 58%
“…The right part contains an area camera (CCD) equipped with a telecentric lens. The OMOP performed well in previous works with different types of apparatuses [19,24,25,27]. The telecentric principle enables a distance-independent imaging of the actual particle sizes without distortion effects.…”
Section: Modified Optical Multimode Online Probementioning
confidence: 58%
“…By combining transmitted light measurement and high‐speed recordings, e.g., it is also possible to precisely observe local phenomena such as coalescence and breakup processes and thus to establish population balances (Fig. ) . This transmitted light method is also able to be adapted to tube flows, bubble columns, and cold‐flow distillation columns from DN 25 to DN 450 , .…”
Section: Measurement Methodsmentioning
confidence: 99%
“…In den letzten zwanzig Jahren wurde dieses Thema verstärkt aufgegriffen [5,76] und bspw. Um an den point of interest in industriell relevanten Größenordnungen von Apparaten zu gelangen ist es aber nötig, mit der Optik und Beleuchtung tiefer in den Apparat einzudringen.…”
Section: Optische Messmethodenunclassified