Droplet‐based electrospray ionization mass spectrometry for qualitative and quantitative analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2015
2015
2017
2017

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 33 publications
(42 reference statements)
0
9
0
Order By: Relevance
“…Nevertheless, the gas‐phase ions with a wide mass range were observed by the mass spectrometer. Several other methods, employing the same principle have also been reported recently . Thus, we believed that a static droplet can function as an ESI source and generate finer droplets for ionization when a suitable setup is established.…”
Section: Introductionmentioning
confidence: 90%
See 2 more Smart Citations
“…Nevertheless, the gas‐phase ions with a wide mass range were observed by the mass spectrometer. Several other methods, employing the same principle have also been reported recently . Thus, we believed that a static droplet can function as an ESI source and generate finer droplets for ionization when a suitable setup is established.…”
Section: Introductionmentioning
confidence: 90%
“…High electric field applied in the mass spectrometer can be used to induce polarization of sample droplets without direct application of a high electric voltage on the sample emitter. As a result, analyte ions in gas phase can be generated via polarization induced ESI processes . For example, in ultrasonication‐assisted spray ionization MS, ultrasonic transducers were used to generate gas‐phase ions from liquid samples in the proximity of a mass spectrometer.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Microdroplets from an automatic pipette at regular time intervals also gave rise to signal MS, speci cally when positioned in proximity to the MS inlet. 87) e droplet from the pipette experienced the polarization e ect due to high voltage at MS inlet. e pressure di erence at the same point allowed the droplet to enter MS ori ce, leading to generation of gas-phase ions.…”
Section: )mentioning
confidence: 99%
“…e pressure di erence at the same point allowed the droplet to enter MS ori ce, leading to generation of gas-phase ions. 87) Recently, another method, called as polarization induced electrospray ionization (PI-ESI), 88) was reported by the same group. Electrospray can be directly generated from a microliter-size droplets (4-10 µL) that is placed over a dielectric material (e.g., a cherry tomato), which is placed close to the inlet of a mass spectrometer, applied with a high voltage (Fig.…”
Section: )mentioning
confidence: 99%