2015
DOI: 10.1016/j.cca.2014.11.007
|View full text |Cite
|
Sign up to set email alerts
|

Dried blood spot assay for the quantification of phenytoin using Liquid Chromatography-Mass Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
10
0
2

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(16 citation statements)
references
References 22 publications
1
10
0
2
Order By: Relevance
“…On the basis of this result, Kong et al developed the following estimation equation: C p = (1.11 × C dbs /[1‐(0.71 × Hct)]) ‐ 1.00 μg/mL. Villanelli et al reported that C dbs was highly correlated with C p after adjusting for Hct levels, which is consistent with findings of other studies ( r 2 = 0.982). However, C p and C dbs were log‐transformed when compared.…”
Section: Aed Concentration Measurement Using Dbs or Dpssupporting
confidence: 74%
“…On the basis of this result, Kong et al developed the following estimation equation: C p = (1.11 × C dbs /[1‐(0.71 × Hct)]) ‐ 1.00 μg/mL. Villanelli et al reported that C dbs was highly correlated with C p after adjusting for Hct levels, which is consistent with findings of other studies ( r 2 = 0.982). However, C p and C dbs were log‐transformed when compared.…”
Section: Aed Concentration Measurement Using Dbs or Dpssupporting
confidence: 74%
“…The development of such methods to measure a range of environmental toxicants, excipients or drugs in DBS has been a more recent goal. The approach has been proved to be effective in the field of neonatal pharmacology, based on compoundspecific reports, for example, caffeine, diphantoine or fenytoine, topiramate, canrenoate, propranolol, linezolid, metronidazole or dexamethasone [39][40][41][42][43][44]49,51].…”
Section: Dsb Sampling Strategiesmentioning
confidence: 99%
“…The technique itself has been introduced already a long time ago in neonatal care to screen for phenylketonuria, and became well established for applications such as the broader neonatal screening for inborn (metabolic) diseases. The same methodological approach has more recently experienced a novel surge of interest in the context of drug development, that is, toxicokinetic and PK studies, and of clinical pharmacotherapy, that is, therapeutic drug monitoring (TDM) [35,[41][42][43][44][45][46][47][48][49][50].…”
Section: Dsb Sampling Strategiesmentioning
confidence: 99%
“…Hence for evaluation of the actual LOD values, the use of the SE-y and limit the range of the regression curve (25-250 and 100-1000 ng/mL for GBL and 1,4-BD respectively) it is considered more appropriate [21].…”
Section: Page 9 Of 20mentioning
confidence: 99%