2021
DOI: 10.1093/icvts/ivab338
|View full text |Cite
|
Sign up to set email alerts
|

Downstream thoracic endovascular aortic repair following zone 2, 100-mm stent graft frozen elephant trunk implantation

Abstract: OBJECTIVES The aim of this study was to analyse outcomes of downstream thoracic endovascular aortic repair (TEVAR) following the frozen elephant trunk (FET) procedure. METHODS Sixty-six patients underwent downstream TEVAR following the FET procedure to treat thoracic aortic dissections (n = 42, 64%), aneurysms (n = 19, 29%) or penetrating aortic ulcers involving the aortic arch (n = 5, 8%). Patient and outcome characteristics… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 10 publications
(21 citation statements)
references
References 21 publications
0
21
0
Order By: Relevance
“…On the one hand, using the short (100 mm) version of the prosthesis may potentially reduce the risk for symptomatic spinal cord injuries, but it may also raise the risk for distal aortic failure due to less aortic coverage ( 3 ). This effect may be aggravated by a trend favoring a zone 2 anastomosis, which simplifies the procedure from the surgical perspective, but proximalis further the distal FET stent-graft landing zone ( 8 ).…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…On the one hand, using the short (100 mm) version of the prosthesis may potentially reduce the risk for symptomatic spinal cord injuries, but it may also raise the risk for distal aortic failure due to less aortic coverage ( 3 ). This effect may be aggravated by a trend favoring a zone 2 anastomosis, which simplifies the procedure from the surgical perspective, but proximalis further the distal FET stent-graft landing zone ( 8 ).…”
Section: Discussionmentioning
confidence: 99%
“…These factors require or might have required additional interventional or surgical treatment to prevent the underlying disease from progressing. Distal aortic failure due to dSINE is a relatively common problem following the FET procedure with higher reported incidences compared to conventional TEVAR ( 8 , 21 ). One possible explanation may be a more rigid ring at the distal end of the FET stent-graft when using the Thoraflex device ( 22 ).…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations