2016
DOI: 10.1109/tpel.2015.2418791
|View full text |Cite
|
Sign up to set email alerts
|

Doubly Fed Induction Generator Wind Turbine Systems Subject to Recurring Symmetrical Grid Faults

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
25
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 34 publications
(25 citation statements)
references
References 32 publications
0
25
0
Order By: Relevance
“…As it can be seen from Fig. 1, the RSC performs effective control of the DFIG stator output power through the rotor current control, the GSC keeps a constant and stable dc-link voltage, either LCL filter [11]- [13] or L filter [6]- [10], [14]- [18] can be adopted to filter out the switching harmonics. A three-terminal step-up transformer is always connected between the DFIG machine stator winding, the GSC output LCL filter and the Point of Common Coupling (PCC) to increase the voltage level of the DFIG system.…”
Section: A Description Of the Dfig System And Weak Networkmentioning
confidence: 99%
See 3 more Smart Citations
“…As it can be seen from Fig. 1, the RSC performs effective control of the DFIG stator output power through the rotor current control, the GSC keeps a constant and stable dc-link voltage, either LCL filter [11]- [13] or L filter [6]- [10], [14]- [18] can be adopted to filter out the switching harmonics. A three-terminal step-up transformer is always connected between the DFIG machine stator winding, the GSC output LCL filter and the Point of Common Coupling (PCC) to increase the voltage level of the DFIG system.…”
Section: A Description Of the Dfig System And Weak Networkmentioning
confidence: 99%
“…where, G c (s) is the PI current controller in (1), G d (s) is the digital control delay in (14), G p (s) is the control subject DFIG transfer function defined as G p (s) = 1/(R r +sσL r ) in [16], R r is the rotor resistance, L r = L m + L σr is the rotor inductance, L m is the mutual inductance, L σr is the rotor leakage inductance.…”
Section: Influence Of the Current Controller Parametersmentioning
confidence: 99%
See 2 more Smart Citations
“…As the distributed generation develops fast, the increasing capacity of wind power generation has been achieved by connecting more and more DFIG based wind turbine systems to offshore and distributed networks [4]- [8]. These types of networks are typically smaller scale weak networks with comparatively large network impedances compared to the stiff grid network.…”
Section: Introductionmentioning
confidence: 99%