2016
DOI: 10.1140/epjd/e2015-60533-5
|View full text |Cite
|
Sign up to set email alerts
|

Double dark resonance in inverted Y system and its application in attenuating the optical switching action

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2017
2017
2019
2019

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 31 publications
0
7
0
Order By: Relevance
“…For example, a threelevel Λ-type system coupled with a simple 'V'-type system forms an 'N'-type system [21][22][23][24]. Other multilevels systems like 'M'-type [25,26], Y-type [27][28][29], inverted-Y [30][31][32][33][34] etc have also been studied by many groups. The four-level inverted-Y type system has two ground energy levels, one intermediate energy level and one upper energy level.…”
Section: Introductionmentioning
confidence: 99%
“…For example, a threelevel Λ-type system coupled with a simple 'V'-type system forms an 'N'-type system [21][22][23][24]. Other multilevels systems like 'M'-type [25,26], Y-type [27][28][29], inverted-Y [30][31][32][33][34] etc have also been studied by many groups. The four-level inverted-Y type system has two ground energy levels, one intermediate energy level and one upper energy level.…”
Section: Introductionmentioning
confidence: 99%
“…As the strength Ω 02 of the probe field is weaker than the strength of all other coupling fields, the probe field can be neglected while evaluating the eigen dressed states corresponding to the Hamiltonian H I in equation 16. The resulting three eigen-frequencies and their corresponding eigen dressed states are…”
Section: Resultsmentioning
confidence: 99%
“…Two promising four level atomic systems, i.e. inverted Y [12][13][14][15][16][17] and N configuration [18][19][20][21][22][23][24][25], have already been earmarked for their application in non-linear spectroscopy for producing large Kerr non-linearities in an optical medium [26,27]. These third order non-linear effects relies on large field strengths to obtain considerably enhanced third order optical susceptibility.…”
Section: Introductionmentioning
confidence: 99%
“…The ideal three-level EIT system creates a dark state which does not interact with the probe field and result in the transmission of probe. The researchers have further investigated this dark state by applying pertubation through a microwave field [22], radio-frequency field [23] and an additional coupling field [24][25][26][27][28], and in these cases a dual EIT structure has been observed. Niu [29] had earlier reported that the four-level EIT (dual structure) shows greatly enhanced non-linear effects than an ideal EIT obtained through three-level system.…”
Section: Introductionmentioning
confidence: 99%