2012
DOI: 10.1016/j.radonc.2011.06.005
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetric study of volumetric modulated arc therapy fields for total marrow irradiation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
61
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 61 publications
(65 citation statements)
references
References 22 publications
4
61
0
Order By: Relevance
“…All treatment plans to date have used a beam energy of 6 MV, however, the retrospective planning study presented in this manuscript aims to investigate the effects of using a 10 MV beam for TMI VMAT fields in comparison to 6 MV. High energy beams (10–18 MV) have historically been a part of TBI treatments, particularly for patients of thickness greater than 35 cm;3, 22 however, published experience with modulated TMI fields has been limited to 6 MV IMRT and VMAT or helical tomotherapy 14, 15, 23, 24, 25, 26, 27, 28. Potential disadvantages of increasing beam energy include larger penumbra and the production of secondary neutrons originating in the head of the linac.…”
Section: Introductionmentioning
confidence: 99%
“…All treatment plans to date have used a beam energy of 6 MV, however, the retrospective planning study presented in this manuscript aims to investigate the effects of using a 10 MV beam for TMI VMAT fields in comparison to 6 MV. High energy beams (10–18 MV) have historically been a part of TBI treatments, particularly for patients of thickness greater than 35 cm;3, 22 however, published experience with modulated TMI fields has been limited to 6 MV IMRT and VMAT or helical tomotherapy 14, 15, 23, 24, 25, 26, 27, 28. Potential disadvantages of increasing beam energy include larger penumbra and the production of secondary neutrons originating in the head of the linac.…”
Section: Introductionmentioning
confidence: 99%
“…Each isocentre receives two 360 degree VMAT arcs. As per previous planning studies, offset arcs with a 4 cm overlap and 90° collimator produced the best dose distribution 11, 13, 14. These are then optimized in stages on a 5 mm dose grid.…”
Section: Methodsmentioning
confidence: 77%
“…Helical tomotherapy (HT) based methods have been used for TMI/TMLI2, 3, 4, 5 as well as TBI 5, 6, 7. Using conventional linacs, intensity modulated radiotherapy (IMRT) TMI delivery proved feasible,8, 9 however, the predominant linac approach utilizes volumetric modulated arc therapy (VMAT) using Varian RapidArc (Varian Medical Systems, Palo Alto, CA, USA) 10, 11, 12, 13, 14, 15, 16, 17…”
Section: Introductionmentioning
confidence: 99%
“…It has also been established in the literature that in order to achieve improved dose sparing for lungs, it is more important to reduce the lower doses to larger lung volume than to reduce the higher doses to lesser volume 11 , 19 . This has been achieved using AMT‐TBI which successfully manipulates lung doses to recommended tolerance levels.…”
Section: Discussionmentioning
confidence: 99%
“…Constant and variable bed velocity TBI, aperture modulated TBI, and radiological depth‐based TBI are a few examples of dynamic TBI techniques 1 , 4 , 5 , 8 , 9 . Some other techniques suggest the use of sweeping arc fields similar to volumetric‐modulated arc therapy (VMAT) techniques 10 , 11 …”
Section: Introductionmentioning
confidence: 99%