Dosimetric parameters for small field sizes using Fricke xylenol gel, thermoluminescent and film dosimeters, and an ionization chamber

Abstract: Dosimetric measurements in small therapeutic x-ray beam field sizes, such as those used in radiosurgery, that have dimensions comparable to or smaller than the build-up depth, require special care to avoid incorrect interpretation of measurements in regions of high gradients and electronic disequilibrium. These regions occur at the edges of any collimated field, and can extend to the centre of small fields. An inappropriate dosimeter can result in an underestimation, which would lead to an overdose to the pati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
22
0
9

Year Published

2009
2009
2020
2020

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 54 publications
(33 citation statements)
references
References 23 publications
2
22
0
9
Order By: Relevance
“…The difference between measurements and calculations is reduced by increasing ield sizes due to decreasing of lateral electronic disequilibrium. The same result has been reported by Oliveira and Calcina for The Fricke Xylenol Gel dosimeter (FXG) compared with other dosimeters in small photon ields (5,18) .…”
Section: Discussionsupporting
confidence: 85%
“…The difference between measurements and calculations is reduced by increasing ield sizes due to decreasing of lateral electronic disequilibrium. The same result has been reported by Oliveira and Calcina for The Fricke Xylenol Gel dosimeter (FXG) compared with other dosimeters in small photon ields (5,18) .…”
Section: Discussionsupporting
confidence: 85%
“…Küçük alan RDF'lerinde TLD ve PinPoint iyon odası benzer okumalar göstermiştir. Bu sonuçlar literatürle uyumlu bulunmuştur 14,17 . Çalışmamız ve diğer literatürlerdeki benzer çalışmaların sonuçlarını dikkate aldığımızda, küçük alanların dozimetrik parametrelerini değerlendirirken karşılaştığımız lateral elektron dengesizliği ve dozimetre hacminin alan boyutuna uygun olacak şekilde seçimi önem taşımaktadır.…”
Section: İyon Odası Ile Yapılan öLçüm Sonuçlarıunclassified
“…Other complication is the perturbation of the level of disequilibrium, which is inducted bye the dosimeter when introduced in the track of the radiation fields. Thus, due these characteristics of the small fields, an accurate dose verification of the delivery dose of the small radiation fields is required [42][43][44][45].…”
Section: Dose-distribution Of Small Fields Through the Magic-f Dosimementioning
confidence: 99%