Dosimetric impact of mechanical movements of the Linac gantry during treatments with small fields

Abstract: ObjectiveCurrent accepted linac Quality Assurance (QA) guidelines used for Volumetric Modulated Arc Therapy (VMAT) suggest a mechanical isocentre tolerance level of 1 mm. However, this tolerance level has not been well-established for the specific case of small field stereotactic VMAT. This study aims to evaluate the clinical impact of mechanical uncertainty on this treatment modality by modelling systematic gantry sag derived isocentre variance in the Treatment Planning System (TPS).ApproachA previously repor… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 20 publications
1
3
0
Order By: Relevance
“…and McCallum‐Hee et al. reported that the effect of gantry sag is conspicuous in rotational irradiation using small fields 28,29 . Gantry sag could be the reason for the variation in coplanar and non‐coplanar beams using the 0.5 × 0.5 cm 2 field in this study.…”
Section: Discussionsupporting
confidence: 46%
See 2 more Smart Citations
“…and McCallum‐Hee et al. reported that the effect of gantry sag is conspicuous in rotational irradiation using small fields 28,29 . Gantry sag could be the reason for the variation in coplanar and non‐coplanar beams using the 0.5 × 0.5 cm 2 field in this study.…”
Section: Discussionsupporting
confidence: 46%
“…This effect is considered to be caused by reported that the effect of gantry sag is conspicuous in rotational irradiation using small fields. 28,29 Gantry sag could be the reason for the variation in coplanar and non-coplanar beams using the 0.5 × 0.5 cm 2 field in this study. In addition, owing to the variety of detectors in this study, there was a detector-specific uncertainty.…”
Section: Discussionmentioning
confidence: 70%
See 1 more Smart Citation
“…Regular QA assessments of the FSP are uncommon, with the primary focus being on beam symmetry, flatness, field size, and radiation isocentre location. These aspects are under consideration in linac QA procedures as an indirect approach to FSP QA; however, a need to assess FSP directly and identify action levels related to FSP has been established 9,10 . The FSP will have an impact on the calibration of MLCs and jaws and the radiation isocentre position.…”
Section: Introductionmentioning
confidence: 99%
“…Các nhà vật lí y khoa lâm sàng có nhiệm vụ kiểm tra định kì cho thiết bị này luôn đạt chất lượng khi cung cấp bức xạ. Công việc này phức tạp và cần sự chính xác cao trong từng phép kiểm tra về cơ học cũng như về liều, và mỗi phép kiểm tra phải tuân thủ theo quy trình và sai số đã được quy định hoặc khuyến Hình 1 Ảnh hưởng của việc điểm đồng tâm của máy gia tốc tuyến tính bị lệch (từ lệch tâm quay và góc quay) lên khả năng bao phủ khối u khi xạ trị, khi điểm đồng tâm này lệch trên 1 mm, độ bao phủ này bị ảnh hưởng nhiều, có thể lên đến 20% [1].…”
unclassified