1984
DOI: 10.1016/0360-3016(84)90036-1
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetric evaluation of a pencil-beam algorithm for electrons employing a two-dimensional heterogeneity correction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
61
1

Year Published

2007
2007
2024
2024

Publication Types

Select...
8

Relationship

5
3

Authors

Journals

citations
Cited by 72 publications
(65 citation statements)
references
References 6 publications
2
61
1
Order By: Relevance
“…The two cylindrical phantoms used in this study were the same ones Hogstrom et al (10) used to evaluate the accuracy of the first commercial implementation of the PBA for patients previously treated for a retromolar trigone and nose cancer. The axial cross section of each phantom was based on the mid‐PTV CT scan of a patient.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The two cylindrical phantoms used in this study were the same ones Hogstrom et al (10) used to evaluate the accuracy of the first commercial implementation of the PBA for patients previously treated for a retromolar trigone and nose cancer. The axial cross section of each phantom was based on the mid‐PTV CT scan of a patient.…”
Section: Methodsmentioning
confidence: 99%
“…Carver et al (9) measured electron dose distributions for bolus ECT plans on cylindrical patient‐based phantoms of the retromolar trigone and nose (10) . These measurements were used to evaluate the accuracy of the pencil beam algorithm (PBA) in the Pinnacle 3 TPS (Philips Healthcare, Andover, MD) and the pencil beam redefinition algorithm (PBRA) in the p.d software (.decimal, LLC, Sanford, FL) used for designing bolus ECT.…”
Section: Introductionmentioning
confidence: 99%
“…The high dose‐gradient regions were defined as the penumbra and distal falloff areas with doses between 10% and 90% of the prescription dose. DTA was defined as the minimum distance from a dose point in the MVCT image to a point in the kVCT image with the same dose 10 , 12 . Each point in the MCVT dose matrix was tested against a square region in the kVCT image of size 1.7×1.7cm centered on the location of the test point.…”
Section: Methodsmentioning
confidence: 99%
“…( 7 , 8 , 11 ) The initial energy spectrum is unique to the PBRA and was calculated using the methods of Boyd et al (2) …”
Section: Methodsmentioning
confidence: 99%
“…The PBA incorporated a formalism whereby rectangular‐field percent depth dose was required as input into the algorithm. ( 7 , 8 ) Rectangular‐field percent depth dose was determined using the square root method from depth doses for two square fields, which were interpolated from a family of measured percent depth dose curves.…”
Section: Introductionmentioning
confidence: 99%