2013
DOI: 10.4236/ijmpcero.2013.21005
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetric Comparison of Craniospinal Axis Irradiation (CSI) Treatments Using Helical Tomotherapy, Smartarc<sup>TM</sup>, and 3D Conventional Radiation Therapy

Abstract: Purpose: Craniospinal axis irradiation (CSI) is a method of treating various central nervous system malignancies. The large target volume typically includes entire spinal cord and whole brain. Dosimetric comparison was performed between tomotherapy, volumetric modulated arc therapy (VMAT), and 3D conformal radiation therapy (3D-CRT) for CSI. Methods and Materials: Five (n = 5) CSI patients were planned using 3D-CRT, VMAT, and tomotherapy (normalized such that 95% of PTV received at least 23.4 Gy in 13 fraction… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0
2

Year Published

2014
2014
2022
2022

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(17 citation statements)
references
References 17 publications
0
15
0
2
Order By: Relevance
“…The plan approval clinical criteria required that 95% of the planning target volume (PTV) should receive at least the prescription dose, and the dose to the involved critical organs (lungs, heart, kidneys, orbits, liver, colon, thyroid, and breasts for the female patients) should be below their tolerance limits as defined in the QUANTEC report (8) . The PTV encompassed the whole brain and the entire spinal cord with a 0.7 cm isotropic expansion (7) . The patient's respective physician delineated all the structures and defined the dose prescription prior to planning, and those factors were kept unchanged during the production of all the plans in each individual case.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The plan approval clinical criteria required that 95% of the planning target volume (PTV) should receive at least the prescription dose, and the dose to the involved critical organs (lungs, heart, kidneys, orbits, liver, colon, thyroid, and breasts for the female patients) should be below their tolerance limits as defined in the QUANTEC report (8) . The PTV encompassed the whole brain and the entire spinal cord with a 0.7 cm isotropic expansion (7) . The patient's respective physician delineated all the structures and defined the dose prescription prior to planning, and those factors were kept unchanged during the production of all the plans in each individual case.…”
Section: Methodsmentioning
confidence: 99%
“…The outcome of the plan can depend heavily on not only the dose given to normal tissues and the target, but also the specific dose distribution and the dose response of the involved organs. Relevant studies have been published concerning these outcomes for adult patients of varying disease sites for different treatment modalities using dosimetric and radiobiological analyses (6,7) . These studies, however, are limited in their applicability to pediatric CSI patients due to the different radiosensitivity that characterizes these young patients.…”
Section: Introductionmentioning
confidence: 99%
“…Fractions of 1.8 Gy were prescribed to a total number of 13 fractions for each plan. The different plans were optimized to meet the acceptance criteria according to which at least 95% of the volume of the PTV should receive the prescribed dose (37). A single planner designed, evaluated, and completed each of the plans for all the modalities involved according to institutional policies for purposes of consistency.…”
Section: Treatment Setup Prescription and Modalitiesmentioning
confidence: 99%
“…Dozimetrik olarak daha üstün bir plan olmasına rağmen tedavi süresinin uzun olması intrafraksiyon organ hareketine sebep olabileceği düşüncesini doğurmaktadır. [20,21] Bizim çalışmamızda da tedavi süresi IMRT planlarına göre oldukça yüksek çıkmıştır. Ayrıca yapılan çalışmada tomoterapi ile yapılan planda tüm vücut dozu diğer planlama sistemlerine göre daha fazla çıktığı görüldü.…”
Section: İntegral Dozunclassified
“…Myers ve ark.nın [20] yaptığı çalışmaya göre tomoterapi planları, 5 cm alan genişliği, 0.287 pitch değerinde ve 2 modülasyon faktöründe oluşturuldu. Tedavi sürelerini ortalamada 1902.1s olarak buldular.…”
Section: İntegral Dozunclassified