Dosimetric Comparison between Monaco TPS and EGSnrc Monte Carlo simulation on Titanium Rod in 12bit and 16bit Image Format

Abstract: This study purpose is to investigate the effects of using different bit depth DICOM images for the 6 MV photon beam on a titanium rod. An EGSnrc Monte Carlo simulation on the Elekta Synergy LINAC executed as a dosimetry comparison tool for the TPS. CT scanners with 12-bit, 12-bit extended (Siemens Somatom Definition AS) and 16-bit depth (Toshiba Aquilion) parameters were applied to scan a wax phantom with a titanium rod. A direct beam (AP) with a field size of 10 x 10 cm2 was prescribed 200 cGy dose and was pl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 18 publications
0
9
0
Order By: Relevance
“…Numerous studies have also employed EGSnrc MC simulation to evaluate the effect of hip prosthesis and compared to the TPS algorithms. Jayamani et al, [18] investigated the effect of titanium rod on 12-bit, 12bit extended and 16-bit depth CT data set for 6 MV photon beam using EGSnrc MC simulation and compared with Monaco TPS calculated dose. In their study, a wax phantom with a titanium rod was used to evaluate the dose at Dmax, at the entrance point before the titanium rod, at the point within the titanium and the exit point from the titanium rod.…”
Section: Resultsmentioning
confidence: 99%
“…Numerous studies have also employed EGSnrc MC simulation to evaluate the effect of hip prosthesis and compared to the TPS algorithms. Jayamani et al, [18] investigated the effect of titanium rod on 12-bit, 12bit extended and 16-bit depth CT data set for 6 MV photon beam using EGSnrc MC simulation and compared with Monaco TPS calculated dose. In their study, a wax phantom with a titanium rod was used to evaluate the dose at Dmax, at the entrance point before the titanium rod, at the point within the titanium and the exit point from the titanium rod.…”
Section: Resultsmentioning
confidence: 99%
“…13 The Elekta Synergy Agility LINAC was modelled and validated in the recent publication. 14 Default PRESTA parameter for 6 MV photon beam was utilised with the energy cut-off for the electron, and photon was fixed to 0•7 MeV and 0•01 MeV, respectively. The phantom model was simulated in the EGSnrc code with 0•4 cm voxel size and was validated using the point dose measurement.…”
Section: Monte Carlo Simulation and Validationmentioning
confidence: 99%
“…The incident electron kinetic energy and FWHM applied were 6.4 MeV and 1 mm, respectively, referring to previous publication. [ 19 ] The information about the particle histories including the particle's position, direction, and energy was stored in the phase-space file after the simulation process in BEAMnrc/EGSnrc was completed. Each field size produces a Phase-space file to analyze the S c , S cp values.…”
Section: Aterials and M Ethodsmentioning