2004
DOI: 10.1016/j.brachy.2004.09.006
|View full text |Cite
|
Sign up to set email alerts
|

Dosimetric characterization of radioactive sources employed in prostate cancer therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
5

Year Published

2005
2005
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 24 publications
0
3
0
5
Order By: Relevance
“…The code is the latest version of MCNP. MCNP and its sister code MCNPX ͑the extension for particle type and energy ranges of MCNP͒ have been used by many authors for brachytherapy seed studies, 4,6,7,[11][12][13][14][15][16][17][18][19] so their feasibility and appropriateness have been well verified. There are several tally types available in MCNP5 for scoring the dose rate.…”
Section: Iib Monte Carlo Simulationmentioning
confidence: 99%
“…The code is the latest version of MCNP. MCNP and its sister code MCNPX ͑the extension for particle type and energy ranges of MCNP͒ have been used by many authors for brachytherapy seed studies, 4,6,7,[11][12][13][14][15][16][17][18][19] so their feasibility and appropriateness have been well verified. There are several tally types available in MCNP5 for scoring the dose rate.…”
Section: Iib Monte Carlo Simulationmentioning
confidence: 99%
“…Other more detailed compositions, up to 33 elements, have already been studied by other authors. 24 However, insignificant differences have been reported and, from a dosimetry standpoint, the ten-element composition is equivalent to the 33element composition. 24 The prostate tissue is considered to be homogeneous and the tissue density is set constant to 1.045 g / cm 3 .…”
Section: Monte Carlo In Prostate Tissue "Mcp…mentioning
confidence: 99%
“…The TG-43u1 calculations overestimate the D 90 values calculated with MCP by 5.8%-12.8%, depending on the seed density and prostate size. This difference corresponds to [13][14][15][16][17][18][19][20][21][22][23][24][25][26] Gy. This is illustrating the systematic effect when taking into account the interseed attenuation and prostate composition corrections in the dosimetry.…”
Section: Overall Comparisonmentioning
confidence: 99%
“…A fonte de 192 Ir é um emissor gama e possui aproximadamente 17 linhas de emissão, onde o valor médio é de 397 keV [23]. O espectro de radiação primário usado nas simulações, foi composto pelas 17 linhas mais prováveis de 65 keV à 1378 keV [24]. A geometria da fonte clínica de 192 Ir, Varian modelo GammaMed Plus, foi modelada consistido em um cilindro de parte ativa de 192 Ir com 0,35 cm de comprimento e 0,03 cm de raio.…”
Section: Modelagem Da Fonte Com O Pacote Penelopeunclassified