Dosimetric characterization of a large area pixel-segmented ionization chamber

Abstract: A pixel-segmented ionization chamber has been designed and built by Torino University and INFN. The detector features a 24 x 24 cm2 active area divided in 1024 independent cylindrical ionization chambers and can be read out in 500 micros without introducing dead time; the digital charge quantum can be adjusted between 100 fC and 800 fC. The sensitive volume of each single ionization chamber is 0.07 cm3. The purpose of the detector is to ease the two-dimensional (2D) verifications of fields with complex shapes … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
82
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 74 publications
(85 citation statements)
references
References 13 publications
(9 reference statements)
0
82
0
Order By: Relevance
“…1. The design and construction of MatriXX were reported by Amerio et al (13) The dose distribution of MatriXX was measured in the movie mode with a sampling rate of 200 ms/snap. This high sampling rate was used to resolve gantry angle differences for VMAT plans with arc segments and to confirm the behavior of dynamic MLC during the radiation for IMRT plans.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…1. The design and construction of MatriXX were reported by Amerio et al (13) The dose distribution of MatriXX was measured in the movie mode with a sampling rate of 200 ms/snap. This high sampling rate was used to resolve gantry angle differences for VMAT plans with arc segments and to confirm the behavior of dynamic MLC during the radiation for IMRT plans.…”
Section: Methodsmentioning
confidence: 99%
“…One such device is the 2D ionization chamber array I'mRT MatriXX (IBA Dosimetry, Bartlett, TN). Amerio et al (13) described the design and construction of I'mRT MatriXX, whereas Herzen et al (17) extensively evaluated its dosimetric properties. The clinical application of I'mRT MatriXX has been reported in numerous studies 13 , 15 , 17 , 19 .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The physical and dosimetric properties of this device have been reported previously 12, 13, 14, 15, 16, 17. The chamber center‐to‐center separation is 0.762 cm, with a sensitive volume of 0.08 cm 3 (0.45 cm in diameter and 0.5 cm in height), covering a 24.4 × 24.4 cm 2 active area.…”
Section: Methodsmentioning
confidence: 91%
“…The 2D detector arrays based on ionization chambers play a major role in QA, but most of these are not suitable for in vivo 2D dose mapping 10 , 13 , 14 , 15 , 16 , 17 , 18 . 2D semiconductor based on diodes approaches, such as MapCHECK (Sun Nuclear Corp., Melbourne, FL) 5 , 11 , 19 , 20 , 21 and the quality control (QA) device, (22) have also been used for dose verification.…”
Section: Introductionmentioning
confidence: 99%