Dosimetric characteristics with spatial fractionation using electron grid therapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
31
0

Year Published

2007
2007
2024
2024

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 25 publications
(34 citation statements)
references
References 6 publications
3
31
0
Order By: Relevance
“…Whereas the low-dose bystander effect in a biological system is of relevance to carcinogenesis and could have serious implications for radiation risk assessment, the bystander signaling induced by a high dose has therapeutic implications. High-dose RIBEs could be the underlying mechanism involved in a novel treatment modality, such as high-dose spatially fractionated radiation GRID therapy for management of advanced cancers (33)(34)(35)(36)(37). Significant induction of LDL-enriched ceramide, secretory SMase, and TNF-a in serum from patients treated with spatially fractionated Figure 5.…”
Section: Discussionmentioning
confidence: 99%
“…Whereas the low-dose bystander effect in a biological system is of relevance to carcinogenesis and could have serious implications for radiation risk assessment, the bystander signaling induced by a high dose has therapeutic implications. High-dose RIBEs could be the underlying mechanism involved in a novel treatment modality, such as high-dose spatially fractionated radiation GRID therapy for management of advanced cancers (33)(34)(35)(36)(37). Significant induction of LDL-enriched ceramide, secretory SMase, and TNF-a in serum from patients treated with spatially fractionated Figure 5.…”
Section: Discussionmentioning
confidence: 99%
“…( 1 3 ) The technique has shown high efficacy for bulky tumors receiving doses of 10 to 20 Gy in a single fraction. ( 2 ) The biological mechanisms of this technique are not fully understood, although several theories have been proposed. ( 2 ) For patients who undergo GRID therapy followed by conventional fractionated radiation therapy, it has been speculated that the high cell kill of the GRID fraction induces re‐oxygenation, which improves the outcome of the subsequent conventional radiation therapy.…”
Section: Introductionmentioning
confidence: 99%
“…( 2 ) The biological mechanisms of this technique are not fully understood, although several theories have been proposed. ( 2 ) For patients who undergo GRID therapy followed by conventional fractionated radiation therapy, it has been speculated that the high cell kill of the GRID fraction induces re‐oxygenation, which improves the outcome of the subsequent conventional radiation therapy. ( 4 ) Furthermore, despite the large single fraction, minimal skin radiation side effects are observed with spatially fractionated radiotherapy since only a small portion of the skin is exposed.…”
Section: Introductionmentioning
confidence: 99%
“…In the high-dose regions, discrepancies between the measured and calculated dose values were within 2%, in accordance to the increased precision of the radiochromic film dosimetry system at higher doses. 15 Results presented in Table 1 and Figures 3 and 5 indicate that the commissioning process for the grid block incorporation into the Eclipse TPS described in this work results in acceptable dosimetric accuracy. In addition, the incorporation of the grid block into the R&V system provides a safe way of treatment and prevents an adverse dose delivery that could be implicated by an attempt to deliver a plan with a field size larger than 25 3 25 cm at the isocentre plane.…”
Section: Resultsmentioning
confidence: 75%
“…Grid holes have a diameter of 1.4 and 2.1 cm centre-to-centre spacing when projected at an orthogonal to the beam plane 100 cm from the source. The actual grid block design was based on the previous work of Meigooni et al 15 and Stathakis et al 16 To measure the size of the holes and their spacing, we irradiated a piece of EBT3 model GAFCHROMIC TM film (Ashland, Wayne, NJ) positioned at the isocentre (Figure 2d). The beam centre was first marked on the film piece prior to insertion of the grid block using the beam cross hair.…”
Section: Grid Treatment Planning System Commissioningmentioning
confidence: 99%