2017
DOI: 10.1109/trpms.2017.2705727
|View full text |Cite
|
Sign up to set email alerts
|

Dose Volume Distribution in Digital Breast Tomosynthesis: A Phantom Study

Abstract: Monte Carlo (MC) calculations for breast dosimetry in digital breast tomosynthesis (DBT) require experimental validations. We measured the 3-D dose distribution in breast phantoms, using XR-QA2 radiochromic films, compared to dose maps obtained with a previously validated MC code. Film sheets were positioned at the entrance surface, at the bottom surface as well as at four depths between adjacent slabs in the fiveslabs 50-mm-thick phantoms simulating a compressed breast. We employed a homogeneous PMMA phantom,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
14
0

Year Published

2017
2017
2018
2018

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 18 publications
(15 citation statements)
references
References 22 publications
1
14
0
Order By: Relevance
“…Notwithstanding the abovementioned inherent issues with GafChromic™ film, the use of this dosimeter technology in heterogeneous phantoms to assess the dose distribution appears feasible (if sufficient entrance air kerma is delivered) and it confirms previous conclusions of the work of Sarno et al…”
Section: Discussionsupporting
confidence: 82%
“…Notwithstanding the abovementioned inherent issues with GafChromic™ film, the use of this dosimeter technology in heterogeneous phantoms to assess the dose distribution appears feasible (if sufficient entrance air kerma is delivered) and it confirms previous conclusions of the work of Sarno et al…”
Section: Discussionsupporting
confidence: 82%
“…Among the commercially available physical anthropomorphic phantoms, one can mention the 'Rachel' anthropomorphic breast phantom, Gammex 169 and the BR3D breast imaging phantom model 020 as well as the BR3D and the CIRS 073 (www.cirsinc.com/). The Rachel phantom is limited to a use in planar x-ray imaging and currently not available commercially, while the BR3D is manufactured specifically for breast tomosynthesis (Sarno et al 2017b). The multi-modality breast biopsy and sonographic trainer CIRS 073 mimics the heterogeneous appearance of breast tissue under various breast imaging modalities, and has cystic and dense lesions embedded within the breast background.…”
Section: Danail Ivanovmentioning
confidence: 99%
“…A MC code for MGD calculation in X-ray breast imaging was developed and presented in previous papers [19,[21][22][23][24]. It is based on GEANT4 ver.…”
Section: Codementioning
confidence: 99%
“…The Monte Carlo code, adopted in the case of homogeneous breast models, was largely validated versus both literature data and measurements [19,21,23]. In particular, it was validated versus data presented in the AAPM Task Group 195, cases I-III [35].…”
Section: Code Validationmentioning
confidence: 99%