2019
DOI: 10.4103/jmp.jmp_59_19
|View full text |Cite
|
Sign up to set email alerts
|

Dose shadowing and prosthesis involvement for megavoltage photon In vivo diode dosimetry

Abstract: Aim:The aim of the study is to investigate the photon beam perturbations induced by an in vivo diode in combination with prosthesis involvement in a human-like phantom.Materials and Methods:Beam perturbations for 6 MV and 10 MV photons caused by an EDP-203G in vivo diode in combination with prosthesis involvement were studied in a unique water-equivalent pelvic phantom, equipped with bony structures and Ti prosthesis using single fields between 2 × 2 and 15 cm × 15 cm as well as 10 MV lateral opposing fields a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 34 publications
0
4
0
Order By: Relevance
“…The dose shadowing effect of the diode is well documented, and our selective diode use also limits this dose shadowing effect to selected patient cases where a benefit of diode use is greater than the dose shadowing. 6,21 Our data demonstrate a rapid change in practice based on a simple intervention backed by stakeholder and leadership engagement, and a sound rationale for the change. Based on the success of this initiative, we anticipate conducting a similar review process of other potentially low-value practices in our department.…”
Section: F I G U R Ementioning
confidence: 73%
See 3 more Smart Citations
“…The dose shadowing effect of the diode is well documented, and our selective diode use also limits this dose shadowing effect to selected patient cases where a benefit of diode use is greater than the dose shadowing. 6,21 Our data demonstrate a rapid change in practice based on a simple intervention backed by stakeholder and leadership engagement, and a sound rationale for the change. Based on the success of this initiative, we anticipate conducting a similar review process of other potentially low-value practices in our department.…”
Section: F I G U R Ementioning
confidence: 73%
“…Finally, the benefit of unnecessary diode use extends to the patient. The dose shadowing effect of the diode is well documented, and our selective diode use also limits this dose shadowing effect to selected patient cases where a benefit of diode use is greater than the dose shadowing 6,21 …”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations