Dose reduction in paediatric cranial CT via iterative reconstruction: a clinical study in 78 patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
4
0
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 19 publications
1
4
0
1
Order By: Relevance
“…Similar to our lower tube voltage settings in certain age groups, Kaul et al ,. incorporated decrease in tube voltage with ASIR and found that 100kV with 20% ASIR was the limit of reductions to allow for adequate image quality.…”
Section: Discussionsupporting
confidence: 89%
“…Similar to our lower tube voltage settings in certain age groups, Kaul et al ,. incorporated decrease in tube voltage with ASIR and found that 100kV with 20% ASIR was the limit of reductions to allow for adequate image quality.…”
Section: Discussionsupporting
confidence: 89%
“…For iterative reconstruction of the raw data, adaptive iterative reconstruction technique (40% adaptive statistical iterative reconstruction, ASIR V, GE Healthcare, Milwaukee, WI, USA) was used in both scan series with the same iterative reconstruction settings (15,16). The Smart MAR post-processing tool (GE Healthcare, Milwaukee, WI, USA) is approved for the reconstruction of iterative primary reconstructions.…”
Section: Ct Image Reconstructionmentioning
confidence: 99%
“…mAs SD 120 kV, 25–200 eff. mAs LD FBP HIR (SAFIRE 2) 20–90 38.1 SD 3.8–30.5 LD NA NA Scholtz [ 55 ] 2017 123 36 SD, SECT 30 SD, DECT 32 LD, SECT 25 LD, DECT SD SECT vs SD DECT vs. LD SECT vs. LD DECT 192-MDCT (Siemens, Siemens Healthineers, Erlangen, Germany) 120 kV, 270 mAs SECT 80/150 kV, 410/273 mAs DECT 120 kV, 270 mAs am, SECT 80/150 kV, 410/273 mAs am, DECT MBIR (ADMIRE) 18 CTDI, SECT 27 CTDI, DECT 25 DLP, SECT 24 DLP, DECT 39.5 SD, SECT 41.0 SD, DECT 32.2 LD, SECT 30.0 LD, DECT 771.5 SD, SECT 770.6 SD, DECT 575.0 LD, SECT 587.0 LD, DECT NA Kaul [ 37 ] 2016 78 18 SD 22 LD1 20 LD2 18 LD3 SD FBP vs. LD1 FBP vs. LD2 ASIR20 vs. LD3 ASIR30/40 64-MDCT (GE Lightspeed VCT, GE Healthcare, Milwaukee, WI, USA) 120 kV, 100–300 mA am, SD 100 kV, 100–300 mA am, LD1–3 FBP HIR (ASIR 20–40%) 20/43/66 CTDI 23/34/64 DLP 31.9 SD 25.4 LD1 18.3 LD2 10.8 LD3 396.0 SD 304.0 LD1 260.0 LD2 141.0 LD3 NA Bodelle [ 56 ] 2014 94 54 SD 40 LD SD vs. LD 128-MDCT (Siemens SOMATOM Definition Flash/AS, Siemens Healthineers, Erlangen, Germany) 120 kV, 340 mAs SD 120 kV, 260 mAs LD FBP HIR (SAFIRE 1–5) 29 DLP NA 1045.0 SD 744.0 LD …”
Section: Resultsmentioning
confidence: 99%
“…Four NCCT studies focused on or included patients for ICH evaluation, using heterogeneous study designs and methodologies. Not taking into account simulated LD protocols, dose reductions ranged from 18 to 66% while maintaining sufficient quantitative and qualitative IQ [ 37 , 48 , 55 , 56 ].…”
Section: Resultsmentioning
confidence: 99%