2020
DOI: 10.1007/s10967-020-07110-y
|View full text |Cite
|
Sign up to set email alerts
|

Dose distribution verification in intraoperative radiation therapy using an N-isopropyl acrylamide-based polymer gel dosimeter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 29 publications
0
4
0
Order By: Relevance
“…Various studies have analyzed the MRI response of polymer gels for possible application in radiotherapy dose mapping ([ 58 , 63 ] and references therein). In particular, polymer gels have been investigated for dosimetry in conformal therapy, IMRT, IMAT, IGRT, VMAT and tomotherapy [ 55 , 70 , 83 , 88 , 102 , 105 , 106 , 107 , 108 , 109 , 110 , 111 , 112 , 113 , 114 , 115 , 116 , 117 , 118 , 119 , 120 , 121 , 122 , 123 , 124 , 125 , 126 , 127 , 128 , 129 , 130 , 131 , 132 , 133 , 134 , 135 ], small photon fields [ 136 , 137 , 138 ], stereotactic radiosurgery [ 55 , 139 , 140 , 141 , 142 ], 60-cobalt source [ 143 , 144 ], brachytherapy [ 55 , 85 , 92 , 145 , ...…”
Section: Polyacrylamide Gelsmentioning
confidence: 99%
“…Various studies have analyzed the MRI response of polymer gels for possible application in radiotherapy dose mapping ([ 58 , 63 ] and references therein). In particular, polymer gels have been investigated for dosimetry in conformal therapy, IMRT, IMAT, IGRT, VMAT and tomotherapy [ 55 , 70 , 83 , 88 , 102 , 105 , 106 , 107 , 108 , 109 , 110 , 111 , 112 , 113 , 114 , 115 , 116 , 117 , 118 , 119 , 120 , 121 , 122 , 123 , 124 , 125 , 126 , 127 , 128 , 129 , 130 , 131 , 132 , 133 , 134 , 135 ], small photon fields [ 136 , 137 , 138 ], stereotactic radiosurgery [ 55 , 139 , 140 , 141 , 142 ], 60-cobalt source [ 143 , 144 ], brachytherapy [ 55 , 85 , 92 , 145 , ...…”
Section: Polyacrylamide Gelsmentioning
confidence: 99%
“…Along with the urgent practical needs, 3D dosimeters including Fricke gels, [5][6][7][8][9] polymer gels, [10][11][12] and radiochromic systems (PRESAGE, 13 tetrazolium salts-based dosimeters, 14 iodide-related gels, 15,16 etc.) have been developed rapidly in recent years.…”
Section: Introductionmentioning
confidence: 99%
“…During the duration of the period, numerous types of dosimeters are utilized for a variety of purposes, including dyed polymeric thin plastic film dosimeters, which have been widely applied [5][6][7][8][9][10][11]. Liquid dosimeters [12][13][14][15][16][17][18], gel dosimeters [19][20][21][22] and EPR dosimeters [23][24][25]. Upon exposure to irradiation, the physical and chemical properties of the polymers change in the case of films, accordingly due to induced cross-links, chain detachments and formation of new chemical bonds [26].…”
Section: Introductionmentioning
confidence: 99%