2013
DOI: 10.1016/s1002-0721(12)60298-1
|View full text |Cite
|
Sign up to set email alerts
|

Dose-dependent effects of lanthanum chloride on wear particle-induced aseptic inflammation in a murine air-pouch model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
9
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 41 publications
1
9
0
Order By: Relevance
“…The specific primary antibodies and secondary antibodies used in the experiments were provided by Cell Signaling Technology (Danvers, MA, USA). Titanium (Ti) particles (99.99% purity, 1e3 mm in diameter) were provided by Johnson Matthey Company (Ward Hill, MA, USA) and prepared as previously described [16]. Briefly, possible endotoxin adhering to the particles was removed by treating with 70% ethanol for 48 h and heating at 250 C for 3 h. The particle endotoxin level was then detected (<0.02 EU/mL) using the limulus amebocyte lysate assay.…”
Section: Reagents and Titanium Particlesmentioning
confidence: 99%
“…The specific primary antibodies and secondary antibodies used in the experiments were provided by Cell Signaling Technology (Danvers, MA, USA). Titanium (Ti) particles (99.99% purity, 1e3 mm in diameter) were provided by Johnson Matthey Company (Ward Hill, MA, USA) and prepared as previously described [16]. Briefly, possible endotoxin adhering to the particles was removed by treating with 70% ethanol for 48 h and heating at 250 C for 3 h. The particle endotoxin level was then detected (<0.02 EU/mL) using the limulus amebocyte lysate assay.…”
Section: Reagents and Titanium Particlesmentioning
confidence: 99%
“…The introduction of molybdate slowed down the reduction rate of Ni ions and the peak potential increased. Judging from the peak current value of Curve 2, the reduction of MoO 4 2− ions belongs to the multi-step reduction process, corresponding to Mo 4+ peak at e and Mo 3+ peak at d [19][20][21]. The voltage value shows a delay effect during the formation of the deposition of metal atoms, while the width of the voltage interval provides time for the further deposition of metal atoms.…”
Section: Analysis Of Metal Ion Activitymentioning
confidence: 99%
“…Three different models of osteolysis were adopted: air-pouch [16,29,33,56,57,58,59,60], calvarial [18,53,61,62,63,64] and pin-implantation [65] models. One study compared two methods to induce osteolysis in vivo: fluid pressure and particle injection [55].…”
Section: Gene Expression In Osteolysismentioning
confidence: 99%
“…Opposite to what was observed in vitro, these in vivo studies used only two types of wear particles: Ti [16,29,33,53,55,56,57,58,59,60,64,65], the most employed ones, and PE [18,61,62,63]. The size of Ti particles ranged between 0.1 and 20 µm while PE particles were 7 [61,62,63] or 5.1 [18] µm.…”
Section: Gene Expression In Osteolysismentioning
confidence: 99%
See 1 more Smart Citation