1982
DOI: 10.3109/14017438209100610
|View full text |Cite
|
Sign up to set email alerts
|

Doppler Ultrasound Estimation of Bubble Removal by Various Arterial Line Filters During Extracorporeal Circulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
1

Year Published

1989
1989
2008
2008

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 12 publications
0
6
0
1
Order By: Relevance
“…In addition, pH-stat management was associated with greater CBF relative to alpha-stat and impairment of cerebral autoregulation [16,17]. An increased PaCO 2 value could increase the embolic load to the brain because of the increased cerebral blood ow [18], but the use of membrane oxygenators [19,20] with arterial line ®lters [21,22] has reduced the incidence of microembolization. In addition, most embolization occurs with aortic canulation (before the initiation of CPB), at the onset of CPB, after the release of aortic cross-clamp, and during the early phase of ventricular ejection (before the end of CPB) [23,24] and it might be possible to reduce PaCO 2 level during these periods [18].…”
Section: Discussionmentioning
confidence: 99%
“…In addition, pH-stat management was associated with greater CBF relative to alpha-stat and impairment of cerebral autoregulation [16,17]. An increased PaCO 2 value could increase the embolic load to the brain because of the increased cerebral blood ow [18], but the use of membrane oxygenators [19,20] with arterial line ®lters [21,22] has reduced the incidence of microembolization. In addition, most embolization occurs with aortic canulation (before the initiation of CPB), at the onset of CPB, after the release of aortic cross-clamp, and during the early phase of ventricular ejection (before the end of CPB) [23,24] and it might be possible to reduce PaCO 2 level during these periods [18].…”
Section: Discussionmentioning
confidence: 99%
“…The use of ultrasonic techniques by numerous investigators has confirmed that a principal advantage of arterial filtration is the removal of GME and gross air. 44,45,47,73,78,81,133,137,145,223,235 Overviews of the general theories involved in the GME removal by various bubble traps and filters are described by Galletti and Brecher236 and Pascale.237 Newer information regarding the incidence of cerebrovascular microembolism, assessed by retinal fluorescein angiography, has clearly demonstrated a reduced incidence of vascular occlusions in patients perfused with a flat-plate membrane oxygenator when compared to those perfused with a bubble oxygenator.238 While the number of patients in each group of this report was small, the author suggests less neuropsychological deficits in the membrane oxygenator group. This study, and the more general acceptance of membrane oxygenators for routine CPB in the last few years, indicate that a reduction in the use of a major source of GME (i.e.…”
Section: Clinical Consequencesmentioning
confidence: 99%
“…135,137,145 There has also been an increased emphasis on newer design filters that take advantage of fluid dynamics to separate and remove GME from the blood.239…”
Section: Clinical Consequencesmentioning
confidence: 99%
“…A pulsed Doppler ultrasound system, the CMD10 (Hatteland Instrumentering, Ryken, Norway) [10][11][12] was connected to the arterial line 3 inches downstream of the filter to measure bubble intensity and relative bubble size of the perfusate. A 13-mm inner diameter probe, fitting 3/8-inch tubing, was used and ultrasonic gel was applied to ensure an optimal contact between the probe and the tubing.…”
Section: Equipmentmentioning
confidence: 99%