2008
DOI: 10.1016/j.ultrasmedbio.2007.11.019
|View full text |Cite
|
Sign up to set email alerts
|

Doppler Estimation of Reduced Coronary Flow Reserve in Mice with Pressure Overload Cardiac Hypertrophy

Abstract: Aortic banding produces pressure overload cardiac hypertrophy in mice leading to decompensated heart failure in 4-8 wks, but the effects on coronary blood flow velocity and reserve are unknown. To determine whether coronary flow reserve (CFR) was reduced, we used noninvasive 20 MHz Doppler ultrasound to measure left main coronary flow velocity at baseline (B) and at hyperemia (H) induced by low (1%) and high (2.5%) concentrations of isoflurane gas anesthesia. Ten mice were studied before (Pre) and at 1d, 7d, 1… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
47
1
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 46 publications
(52 citation statements)
references
References 45 publications
3
47
1
1
Order By: Relevance
“…As a coronary vasodilator stimulus, the inhaled isoflurane concentration was increased to 2.5%. The coronary vasodilatory properties of isoflurane in general are well described (47), and we have previously validated its use in the measurement of CFR in conjunction with a noninvasive ultrasound technique (33,48). Ratios of peak velocities at low-(1%) and high-dose (2.5%) isoflurane were reported as CFR.…”
Section: Methodsmentioning
confidence: 98%
See 1 more Smart Citation
“…As a coronary vasodilator stimulus, the inhaled isoflurane concentration was increased to 2.5%. The coronary vasodilatory properties of isoflurane in general are well described (47), and we have previously validated its use in the measurement of CFR in conjunction with a noninvasive ultrasound technique (33,48). Ratios of peak velocities at low-(1%) and high-dose (2.5%) isoflurane were reported as CFR.…”
Section: Methodsmentioning
confidence: 98%
“…Carotid velocities were measured 24 hours, 7 days, and 14 days after TAC using a 20-Mhz ultrasound probe connected to a signal processing unit (Indus Instruments) using our previously published protocol (46). CFR was measured as previously described (33). Briefly, the ultrasound probe tip was placed at the left side of the chest of the anesthetized animal and stabilized using a micromanipulator (model MM3-3, World Precision Instruments).…”
Section: Methodsmentioning
confidence: 99%
“…Measures of coronary velocity reserve under conditions of hypoxia (55), hypertrophy after aortic banding (TAC) (26), and vasodilatation (isoflurane inhalation) (27) have enabled the assessment of coronary microdysfunction during early and late pathological changes in the development of atherosclerosis and heart failure. In myocardial contrast echocardiography, contrast microbubbles agents filled with inert gas reflect sound waves returning to the transducer with increased signal-tonoise ratio.…”
Section: Myocardial Perfusion Assessmentmentioning
confidence: 99%
“…Using the above procedure, we estimated left main CFR in 10 mice before and at several time points for 21 days after TAC (23). Figure 5 shows waveforms at baseline and at hyperemia from one mouse before, 1 day after, and 21 days after TAC.…”
Section: Coronary Flow Reservementioning
confidence: 99%
“…We will focus here on noninvasive ultrasonic Doppler methods, which our group and others have developed and used to evaluate cardiovascular physiology and function in anesthetized mice and which can be used serially to follow changes because of aging, remodeling, and/or the effects of surgical or pharmacological interventions (19,66). The utility and value of the measurements will be illustrated using the widely used model of transverse aortic constriction (TAC) that was developed for producing pressure-overload cardiac hypertrophy and remodeling (51) but which produces numerous other measurable changes in peripheral vascular mechanics and function (23,34). …”
mentioning
confidence: 99%