Does the fixture thread depth affect the accuracy of implant placement during fully guided immediate implant placement?: A human cadaver study

Abstract: Background:The fixture thread depth reportedly influences the primary stability of dental implant, but its effect on the positional accuracy in immediate implant placement has not been reported previously. Materials and Methods:Fifty-six single-rooted, anterior and premolar teeth were extracted from six human cadavers, followed by installing either regular-threaded implants (RT group, N = 30) or deep-threaded implants (DT group, N = 26) completely relying on the surgical guide. Optical impressions taken after … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 24 publications
(53 reference statements)
0
5
0
Order By: Relevance
“…This approach provides clinical advantages in terms of reducing the invasiveness of surgery and enabling accurate placement at the position planned using computer software based on preoperative computed tomography images and intraoral scan data. 1 However, guided surgery does not always guarantee the accuracy, 2 3 especially in the posteriorly extended edentulous area where there are no natural teeth distal to the implant placement site.…”
Section: Introductionmentioning
confidence: 99%
See 4 more Smart Citations
“…This approach provides clinical advantages in terms of reducing the invasiveness of surgery and enabling accurate placement at the position planned using computer software based on preoperative computed tomography images and intraoral scan data. 1 However, guided surgery does not always guarantee the accuracy, 2 3 especially in the posteriorly extended edentulous area where there are no natural teeth distal to the implant placement site.…”
Section: Introductionmentioning
confidence: 99%
“…The positional accuracy of each implant placed using the CP or MP was evaluated by comparing the virtually planned position with the actually placed position using superimposed optical scan data based on the previously reported reverse-engineering method. 2 3 11 …”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations