Does Calipered Kinematically Aligned TKA Restore Native Left to Right Symmetry of the Lower Limb and Improve Function?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
106
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
1
1

Relationship

3
4

Authors

Journals

citations
Cited by 84 publications
(109 citation statements)
references
References 38 publications
2
106
1
Order By: Relevance
“…32 However, Nedopil et al showed that KA TKA restored native left to right symmetry of the hip-knee-ankle angle, distal lateral femoral angle, and proximal medial tibial angle in nearly all patients with negligible risk of varus alignment of the tibial component with respect to the native tibial joint line. 33 In addition, Shelton et al showed that KA TKA has a high proportion of varus or valgus outliers using mechanically aligned criteria; the intraoperative forces in the medial and lateral compartments of patients with outlier alignment were comparable with those with in-range alignment, with no evidence of overload of the medial or lateral compartment of the knee. 34 However, there has been no study that evaluated the biomechanical effects of MA TKA and KA TKA with respect to the contact stresses on the PE insert and patellar button and the forces exerted on the collateral ligaments.…”
Section: Discussionmentioning
confidence: 99%
“…32 However, Nedopil et al showed that KA TKA restored native left to right symmetry of the hip-knee-ankle angle, distal lateral femoral angle, and proximal medial tibial angle in nearly all patients with negligible risk of varus alignment of the tibial component with respect to the native tibial joint line. 33 In addition, Shelton et al showed that KA TKA has a high proportion of varus or valgus outliers using mechanically aligned criteria; the intraoperative forces in the medial and lateral compartments of patients with outlier alignment were comparable with those with in-range alignment, with no evidence of overload of the medial or lateral compartment of the knee. 34 However, there has been no study that evaluated the biomechanical effects of MA TKA and KA TKA with respect to the contact stresses on the PE insert and patellar button and the forces exerted on the collateral ligaments.…”
Section: Discussionmentioning
confidence: 99%
“…It is important to note that because cartilage wear was not present in these specimens, loss of cartilage thickness present in osteoarthritic patients did not have to be accounted for during these in vitro KA TKAs as it does in vivo . When the thicknesses of the femoral resections were within 0.5 mm of the thicknesses of the corresponding regions of the femoral component, the joint lines of the femoral component closely matched those of the native knee …”
Section: Methodsmentioning
confidence: 97%
“…After kinematic alignment of the femoral component was confirmed, kinematic alignment of the tibial component (Zimmer Persona CR) in V‐V, P‐D, and F‐E was confirmed when the knee was stable at 0° of flexion (i.e., had negligible V‐V laxity at 0° of flexion indicated by negligible gapping medially and laterally during a manual laxity assessment as judged visually by the surgeon, which matches the that of the native knee) and had the same A‐P offset of the distal medial condyle of the femur from the anterior cortex of the tibia at 90° of flexion as that in the ACL‐d knee before the distal femoral resections were made . These checks have been shown clinically to result in a V‐V orientation of the tibial component within 0.0° ± 1.8° of that of the contralateral healthy knee and a posterior slope within −0.2° ± 2.5° of the pre‐operative posterior slope . Correct thickness of the tibial insert was confirmed when the full extension position (i.e., flexion‐extension orientation of the tibia relative to the femur when the femur and tibia are simply supported) matched that of the ACL‐d knee before any resections were made.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, whether a high level of knee exion can be achieved with less cutting of the posterior femur bone than with the previous conventional model (NexGen-LPS-Flex® system (Zimmer Biomet, Warsaw, Indiana) remains to be elucidated [21]. To the best of our knowledge, only a few studies have reported short-term outcomes and no study has used this implant system in Asian knees [22,23]. Therefore, the primary aim of our study was to evaluate the clinical outcomes of the Persona® knee system including whether it could achieve a higher level of knee exion.…”
Section: Introductionmentioning
confidence: 99%