2015
DOI: 10.1016/j.healun.2014.11.019
|View full text |Cite
|
Sign up to set email alerts
|

Dobutamine stress echocardiography during follow-up surveillance in heart transplant patients: Diagnostic accuracy and predictors of outcomes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
44
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 56 publications
(46 citation statements)
references
References 35 publications
2
44
0
Order By: Relevance
“…The data presented here, when combined with the recent Cleveland Clinic series 5 puts into question the external validity of the previous studies from nearly 20 years ago that established the evidence for DSE in CAV screening. This study found that DSE failed to diagnose CAV1 and CAV2 in the first five years following HT.…”
Section: Resultsmentioning
confidence: 60%
See 1 more Smart Citation
“…The data presented here, when combined with the recent Cleveland Clinic series 5 puts into question the external validity of the previous studies from nearly 20 years ago that established the evidence for DSE in CAV screening. This study found that DSE failed to diagnose CAV1 and CAV2 in the first five years following HT.…”
Section: Resultsmentioning
confidence: 60%
“…Previous studies reported a good sensitivity (72–95%) and specificity (55–91%) to detect luminal CAV 4 . A recent single center failed to replicate these findings among patients at least five years post-transplant, showing a sensitivity to detect CAV1-CAV3 of only 7–28% 5 . We sought to determine the adequacy of DSE for CAV assessment in the first five years after transplant.…”
Section: Introductionmentioning
confidence: 98%
“…There have been extensive recent comprehensive publications on imaging evaluation of CAV, which is beyond the scope of this present review . Table summarizes imaging modalities utilized for CAV . Invasive coronary angiography is recommended by the International Society of Heart and Lung Transplantation (ISHLT) as the diagnostic gold standard for CAV and for grading of disease severity (Table ) .…”
Section: Imaging Surveillancementioning
confidence: 99%
“…44 Recently, two independent studies including over 500 patients questioned the adequacy of DSE to detect angiographic CAV, finding that in clinical practice the sensitivity of DSE was only 6.5% in ISHLT CAV1, 27% in ISHLT CAV2, and 24% in ISHLT CAV3. 45, 46 …”
Section: Non-invasive Testingmentioning
confidence: 99%