2022
DOI: 10.1039/d2nj02560d
|View full text |Cite
|
Sign up to set email alerts
|

Do eco-friendly binders affect the electrochemical performance of MOF@CNT anodes in lithium-ion batteries?

Abstract: Today, with the advancement of technology, the environment is in danger more than ever. Given the increasing use of lithium-ion batteries (LIBs), it is essential to find more suitable binders...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 87 publications
0
2
0
Order By: Relevance
“…In the electrodes with a carbon fiber current collector, the peak adhesion force of electrodes with PVDF-HFP- g -PSSA is approximately five times more than pristine PVDF and in the electrodes with an aluminum current collector. Better adhesion of PVDF-HFP- g -PSSA leads to more strength when the electrode swells during charge/discharge cycles; thus, it enhances electrode stability, cyclability, and flexibility . The higher adhesion of PVDF-HFP- g -PSSA/carbon fiber electrodes can be assigned to their reinforced interfacial stability due to the π–π interactions of polystyrene moieties of PVDF-HFP- g -PSSA and carbon fiber (Figure ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In the electrodes with a carbon fiber current collector, the peak adhesion force of electrodes with PVDF-HFP- g -PSSA is approximately five times more than pristine PVDF and in the electrodes with an aluminum current collector. Better adhesion of PVDF-HFP- g -PSSA leads to more strength when the electrode swells during charge/discharge cycles; thus, it enhances electrode stability, cyclability, and flexibility . The higher adhesion of PVDF-HFP- g -PSSA/carbon fiber electrodes can be assigned to their reinforced interfacial stability due to the π–π interactions of polystyrene moieties of PVDF-HFP- g -PSSA and carbon fiber (Figure ).…”
Section: Resultsmentioning
confidence: 99%
“…T-peeling tests were conducted on prepared electrodes with different binding materials (PVDF-HFP- g -PSSA and PVDF) and different current collectors (carbon fabric and Al) to examine the adhesion strength of the binders. The testing dimensions of electrodes were 1.7 cm × 10 cm using conventional tape, and the specimens were fixed in an STM-50 (SANTAM) tensile testing machine with a peeling speed of 45 mm min –1 and an angle of 90° …”
Section: Experimental Sectionmentioning
confidence: 99%