2013
DOI: 10.2116/analsci.29.1027
|View full text |Cite
|
Sign up to set email alerts
|

Distribution of the Elements in Cotyledon, Embryonic Axis, and Testa of Peanut Seeds Obtained by ICP-MS with Microwave Acid Digestion

Abstract: Eighteen elements in the cotyledon, the embryonic axis, and the testa of peanut seeds were determined by inductively coupled plasma mass spectrometry (ICP-MS) after microwave acid digestion, while the gravimetric standard addition with internal standard was applied for the calibration of the elemental concentrations. The detection limit and the procedure blank value for each element were low enough to ensure the precise analysis of the elements, with a relative expanded uncertainty of less than 5%. The concent… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
1
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 26 publications
1
1
0
Order By: Relevance
“…The calculation for the concentration and the uncertainty in gravimetric standard addition was carried out based on the equations reported previously by the present authors. 16,17 The observed value of fluorine in ERM-CA015a was (1.36 ± 0.05)mg kg -1 , which agreed with the certified value, i.e. (1.3 ± 0.1)mg kg -1 , indicating that the present method is valid for the analysis of fluorine in drinking water.…”
Section: Analysis Of Fluorine In a Crm For Drinking Water And That Insupporting
confidence: 80%
“…The calculation for the concentration and the uncertainty in gravimetric standard addition was carried out based on the equations reported previously by the present authors. 16,17 The observed value of fluorine in ERM-CA015a was (1.36 ± 0.05)mg kg -1 , which agreed with the certified value, i.e. (1.3 ± 0.1)mg kg -1 , indicating that the present method is valid for the analysis of fluorine in drinking water.…”
Section: Analysis Of Fluorine In a Crm For Drinking Water And That Insupporting
confidence: 80%
“…The applications cover research fields of biology, [33][34][35] cosmetics, [36][37][38] energy, [39][40][41] the environment, [42][43][44] food, [45][46][47] geology, [48][49][50] industry, 51-53 material, [54][55][56] and plants. [57][58][59] The development and application of SAM in these studies proved that SAM is an effective approach for the removal or cancelling of rotational matrix effects in measurements by ICP-MS. On the other hand, the preparation of samples for SAM in a classical way, multiple concentration levels added to the sample, was often thought to be both laborious and timeconsuming. Actually, the earliest idea of SAM, suggested by Hans Hohn in 1937 for polarography, was based on a single level addition approach and had been applied for decades.…”
Section: Introductionmentioning
confidence: 99%