1992
DOI: 10.1007/bf02037434
|View full text |Cite
|
Sign up to set email alerts
|

Distribution and behaviour of99Tc,237Np,239,240Pu, and241Am in the coastal and estuarine sediments of the Irish Sea

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

1993
1993
2013
2013

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 27 publications
(8 citation statements)
references
References 13 publications
0
8
0
Order By: Relevance
“…234 U and 230 Th (Holm and Nilsson, 1980). Due to the low background in the high-mass region and the low detection limit, ICP-MS techniques have been used for several environmental studies of 237 Np, in soil (Bunzl et al, 1995) and sediments (Assinder et al, 1991;Kim et al, 1992;Morris et al, 2000;Kenna and Sayles, 2002). The 240 Pu/ 239 Pu atomic ratio has been determined by the ICP-MS technique in soil (Muramatsu et al, 2000;Muramatsu et al, 2001;Tonouchi et al, 2002) and in the marine environment (Chiappini et al, 1999;Eroglu et al, 1998).…”
Section: Introductionmentioning
confidence: 99%
“…234 U and 230 Th (Holm and Nilsson, 1980). Due to the low background in the high-mass region and the low detection limit, ICP-MS techniques have been used for several environmental studies of 237 Np, in soil (Bunzl et al, 1995) and sediments (Assinder et al, 1991;Kim et al, 1992;Morris et al, 2000;Kenna and Sayles, 2002). The 240 Pu/ 239 Pu atomic ratio has been determined by the ICP-MS technique in soil (Muramatsu et al, 2000;Muramatsu et al, 2001;Tonouchi et al, 2002) and in the marine environment (Chiappini et al, 1999;Eroglu et al, 1998).…”
Section: Introductionmentioning
confidence: 99%
“…By means of a double focusing analyzer the mass resolution is improved and the background is reduced since especially no photons reach the detector due to a longer and more complicated ion flight path and the use of narrow slits and lenses. Such a facility delivers a detection limit of 0.25 pg/ml of ®®®Tc which can further be improved to 8 fg/ml by adding an ultrasonic nebulizer [23,24]. In this way the amount of sample reaching the plasma is increased by at least one order of magnitude from less than 1% to about 10%.…”
Section: Inductively Coupled Plasma Mass Spectrometrymentioning
confidence: 94%
“…Lower detection limit of 0.6 fg for 99 Tc was achieved by integrating electrothermal vaporization and inductively coupled plasma mass spectrometry (ETV-ICP-MS). 195 Kim et al 97 found suitable measurement conditions for SF-ICP-MS and could compare the 99 Tc concentrations with those of other radionuclides such as 137 Cs and Pu. Tagami and Uchida 101 applied ICP-QMS to measure global fallout 99 Tc in Japanese soils and obtained the concentration range of 4-88 mBq kg À1 .…”
Section: Global Fallout Contaminationmentioning
confidence: 99%