2014
DOI: 10.1136/jnnp-2014-308043
|View full text |Cite
|
Sign up to set email alerts
|

Distinct phenotypes of speech and voice disorders in Parkinson's disease after subthalamic nucleus deep brain stimulation

Abstract: Stuttering and breathy voice can be aggravated by STN-DBS, but are mainly due to aging or PD itself. Strained voice and spastic dysarthria are considered corticobulbar side effects.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
64
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 92 publications
(73 citation statements)
references
References 37 publications
3
64
0
Order By: Relevance
“…ILS improved stimulation-induced adverse effects in only 2 out of 9 patients for other stimulation-induced adverse effects. Confirming previous reports [40], dysarthria was the most common stimulation-induced adverse effect ( n = 6). Only in 1 patient (PD5) did reduced stimulation of the pre-ILS contact located within the rZI region and longitudinal current shaping to a ventral contact within the STN permit amelioration of dysarthria.…”
Section: Discussionsupporting
confidence: 78%
“…ILS improved stimulation-induced adverse effects in only 2 out of 9 patients for other stimulation-induced adverse effects. Confirming previous reports [40], dysarthria was the most common stimulation-induced adverse effect ( n = 6). Only in 1 patient (PD5) did reduced stimulation of the pre-ILS contact located within the rZI region and longitudinal current shaping to a ventral contact within the STN permit amelioration of dysarthria.…”
Section: Discussionsupporting
confidence: 78%
“…Rates in monitored trials are very variable and range between <10% and >50% (Table 1). The exact phenotypic characteristics associated with impaired speech intelligibility and the actual functional impairments caused by DBS therapy still require further elucidation and exhibit high individual variability [3039]. Whereas reduced volume is observed in almost all PD patients slurred speech has been regarded rather as a side effect of DBS therapy [38].…”
Section: Discussionmentioning
confidence: 99%
“…DBS may provoke added speech impairments, with greater spasticity and increased dysfluency besides the existing hypokinetic picture 45. Speech–language therapy interventions successful with patients without DBS may not succeed or require modification for DBS treated individuals 46…”
Section: Language Changesmentioning
confidence: 99%