Distance Protection in Distribution Systems: How It Assists With Integrating Distributed Resources

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
43
0
2

Year Published

2016
2016
2022
2022

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 104 publications
(45 citation statements)
references
References 1 publication
0
43
0
2
Order By: Relevance
“…Based on the challenges of relay settings and coordination of the over current relays due the large difference in the fault currents in grid connected and islanded mode, research has been diverted towards the application of distance protection to micro grid in which the tripping decision is based on the impedance seen by the relay and not on the current magnitude [21,22]. The DER output may result in under reach and power drawn by the loads may cause over reach of the distance relays.…”
Section: Distance Protectionmentioning
confidence: 99%
“…Based on the challenges of relay settings and coordination of the over current relays due the large difference in the fault currents in grid connected and islanded mode, research has been diverted towards the application of distance protection to micro grid in which the tripping decision is based on the impedance seen by the relay and not on the current magnitude [21,22]. The DER output may result in under reach and power drawn by the loads may cause over reach of the distance relays.…”
Section: Distance Protectionmentioning
confidence: 99%
“…The unknown values of TD and Ipickup for relay/recloser are to be determined by the optimization process based on simulation results of all fault cases in the fault case packages. The pickup current Ipickup_phase for phase relay/recloser is required to be at least 30% larger than the maximum load current ImaxL, while being less than the minimum phase fault current Imin_phase in the system [22]. The pickup current Ipickup_ground for ground relay/recloser should be at least twice the maximum unbalanced current I0maxL while less than the minimum ground faults in the system, as shown in (2-3) (3)…”
Section: Saving Schemementioning
confidence: 99%
“…Also, including various types of alternative energy sources with intermittent nature, which led to a significant variation in the level of the short-circuit currents during different islanded and grid-connected modes (Saad et al 2017). The considerable change in the short-circuit level in these different operational conditions burdens the operation and performance of overcurrent protection schemes in detecting various kind of faults in the network and make them even improbable to isolate (Sinclair et al 2014). Utilization of distance Protection schemes could seem to be an appropriate alternative for protecting microgrids instead of conventional overcurrent schemes in cases of the weak faults nature.…”
Section: Introductionmentioning
confidence: 99%