2019
DOI: 10.1631/fitee.1800708
|View full text |Cite
|
Sign up to set email alerts
|

Displacement measuring grating interferometer: a review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
26
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 70 publications
(29 citation statements)
references
References 160 publications
0
26
0
Order By: Relevance
“…A Michelsontype interferometer can also be formed by a heterodyne GI, as shown in Figure 19. 55 A polarized laser beam with two frequencies f 1 and f 2 is produced by a dual-frequency laser. The light is split into two beams by a NPBS, one beam is detected by the PD r to form a reference signal, the other beam is divided into two parts by a polarized beam splitter (PBS) and enters the reference grating and the measuring grating respectively.…”
Section: Stage Position Measurementmentioning
confidence: 99%
“…A Michelsontype interferometer can also be formed by a heterodyne GI, as shown in Figure 19. 55 A polarized laser beam with two frequencies f 1 and f 2 is produced by a dual-frequency laser. The light is split into two beams by a NPBS, one beam is detected by the PD r to form a reference signal, the other beam is divided into two parts by a polarized beam splitter (PBS) and enters the reference grating and the measuring grating respectively.…”
Section: Stage Position Measurementmentioning
confidence: 99%
“…Only those beams that forms quadrature signals are shown. However there are other diffraction directions provided by diffraction grating Equation (1) and not used in the optical system in which diffraction efficiency should be minimized. The beam splitting on reference and measurement scales is carried out in accordance with the grating equation…”
Section: Optical Conceptmentioning
confidence: 99%
“…Linear displacement sensors with fixed reading head determine the current coordinate and displacement direction of an object connected with the measurement scale [1][2][3]. Optical interferential sensors show the highest resolution and accuracy for linear displacement measurements.…”
Section: Introductionmentioning
confidence: 99%
“…Due to their high accuracy, robustness against environmental variances, relatively low cost, and compactness, grating encoders now hold more than 75% market share among various precision positioning solutions. Depending on the measurement method, there are two trends of grating encoders; one is single axis ultra-high precision and the other is multi-axis [1][2][3][4][5][6]. For high precision applications, the diffraction beam interferometry principle is utilized.…”
Section: Introductionmentioning
confidence: 99%