2020
DOI: 10.1016/j.jenvman.2020.111360
|View full text |Cite
|
Sign up to set email alerts
|

Disinfection by-products in Croatian drinking water supplies with special emphasis on the water supply network in the city of Zagreb

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0
1

Year Published

2022
2022
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 55 publications
0
8
0
1
Order By: Relevance
“…The concentrations of anions (F − , Cl − , NO 45 was used for determining HAAs (monochloroacetic acid (MCAA), dichloroacetic acid (DCAA), trichloroacetic acid (TCAA), monobromoacetic acid (MBAA) and dichloroacetic acid (DCAA)) (GC-ECD Thermo Fisher Scientific Trace 1300, Waltham, Massachusetts, USA). Further details on the methods used are available in Kurajica et al (2020). 46 A spectrofluorometer (Horiba Aqualog Jobin Yvonn, Kyoto,…”
Section: Physico-chemical Analysis Of Tap Water and Water From Experi...mentioning
confidence: 99%
See 1 more Smart Citation
“…The concentrations of anions (F − , Cl − , NO 45 was used for determining HAAs (monochloroacetic acid (MCAA), dichloroacetic acid (DCAA), trichloroacetic acid (TCAA), monobromoacetic acid (MBAA) and dichloroacetic acid (DCAA)) (GC-ECD Thermo Fisher Scientific Trace 1300, Waltham, Massachusetts, USA). Further details on the methods used are available in Kurajica et al (2020). 46 A spectrofluorometer (Horiba Aqualog Jobin Yvonn, Kyoto,…”
Section: Physico-chemical Analysis Of Tap Water and Water From Experi...mentioning
confidence: 99%
“…Further details on the methods used are available in Kurajica et al (2020). 46 A spectrofluorometer (Horiba Aqualog Jobin Yvonn, Kyoto,…”
Section: Physico-chemical Analysis Of Tap Water and Water From Experi...mentioning
confidence: 99%
“…The data presented a positively skewed distribution, which is characterized by having a large amount of data in the low ranges of the parameter compared to the higher ranges. Therefore, to evaluate the correlation between the variables, Spearman's non-parametric test was used (Kurajica et al 2020).…”
Section: Correlation Of Independent Variables With Thms In Treated Watermentioning
confidence: 99%
“…62,77 It is noteworthy that trichloromethane was the dominant DBP compound, with up to 92% of total THMs and up to 47% of the total organic halogen load, 78 observed from chlorination/chloramination in drinking water treatment plants when bromide concentrations were low. 15,70,[79][80][81][82] According to his major presence, THMs and HAAs were investigated in 90% and 50% of the selected articles, respectively (SI, Table S5) and accounted together for 52% of the total established linear relationships (Figure 3). Humic/fulvic-like components play a significant role in the THMs and HAAs formation potential and exhibit strong relationships (Table 2).…”
Section: Established Relationships Between Parafac Components and Dbp...mentioning
confidence: 99%