2018
DOI: 10.3390/molecules23071525
|View full text |Cite
|
Sign up to set email alerts
|

Discovery of the Potential Biomarkers for Discrimination between Hedyotis diffusa and Hedyotis corymbosa by UPLC-QTOF/MS Metabolome Analysis

Abstract: Hedyotis diffuse Willd. (HD) and Hedyotis corymbosa (L.) Lam. (HC), two closely related species of the same genus, are both used for health benefits and disease prevention in China. HC is also indiscriminately sold as HD in the wholesale chain and food markets. This confusion has led to a growing concern about their identification and quality evaluation. In order to further understand the molecular diversification between them, we focus on the screening of chemical components and the analysis of non-targeted m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
40
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 36 publications
(41 citation statements)
references
References 95 publications
0
40
0
1
Order By: Relevance
“…The optimized MS parameters were as follows: source temperature (150 C), desolvation temperature (400 C), cone voltage (40 V), capillary voltage at 2.6 kV (ESI + ) and 2.2 kV (ESI À ), cone gas ow (50 L h À1 ) and desolvation gas ow (800 L h À1 ). MS E mode was chosen with low energy of 6 V and high energy of 20-40 V. 26,27 The mass spectrometer was calibrated with sodium formate in the range of 100 to 1200 Da in order to ensure the mass reproducibility and accuracy. Leucine enkephalin (m/z 556.2771 in ESI + and 554.2615 in ESI À ) was used as external reference for Lock Spray™ injected at a constant ow of 10 mL min À1 .…”
Section: Ultra-high Performance Liquid Chromatography Combined With Qmentioning
confidence: 99%
“…The optimized MS parameters were as follows: source temperature (150 C), desolvation temperature (400 C), cone voltage (40 V), capillary voltage at 2.6 kV (ESI + ) and 2.2 kV (ESI À ), cone gas ow (50 L h À1 ) and desolvation gas ow (800 L h À1 ). MS E mode was chosen with low energy of 6 V and high energy of 20-40 V. 26,27 The mass spectrometer was calibrated with sodium formate in the range of 100 to 1200 Da in order to ensure the mass reproducibility and accuracy. Leucine enkephalin (m/z 556.2771 in ESI + and 554.2615 in ESI À ) was used as external reference for Lock Spray™ injected at a constant ow of 10 mL min À1 .…”
Section: Ultra-high Performance Liquid Chromatography Combined With Qmentioning
confidence: 99%
“…Main parameters were set as follows: peak intensity of high energy over 200 counts and the peak intensity of low energy over 1000 counts were the selected parameters in peak detection; mass error up to ±10 ppm for identified compound; retention time tolerance was set in the range of ±0.1 min; positive adducts containing +H, +Na or negative adducts containing −H, +HCOOH were all selected; the reference compound was leucine-enkephalin (556.2766 for positive ion, 554.2620 for negative ion). The MS raw data were processed using the streamlined workflow of UNIFI software to quickly identify the chemical components that met the match criteria with the in-house Traditional Medicine Library and the self-built database [20,21].…”
Section: The Screening Analysis Based On Unifi Platformmentioning
confidence: 99%
“…To differentiate MCG and CG, MarkerLynx XS V4.1 software (Waters, Milford, DE, USA) was used to process the raw data by deconvolution, alignment, data reduction and to perform the multivariate statistical analysis [20,21]. The following steps were performed: acquiring data, creating a MarkerLynx processing method, processing the acquired data and viewing results Extended Statistics (XS) Viewer.…”
Section: The Metabolomics Analysis Based On Multivariate Statisticalmentioning
confidence: 99%
See 2 more Smart Citations