2010
DOI: 10.1016/j.arth.2009.03.001
|View full text |Cite
|
Sign up to set email alerts
|

Disassembly of a Modular Femoral Component After Femoral Head Prosthetic Replacement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
18
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(18 citation statements)
references
References 5 publications
0
18
0
Order By: Relevance
“…In head-neck dissociation, postulated mechanisms include strong distraction forces caused by the inferior edge of the femoral head becoming caught on the rim of the acetabular component during reduction of a dislocation [ 19 ] and excessive external rotation in the presence of a constrained liner, in which the elevated liner would act as a fulcrum at the head and neck junction [ 6 ]. However, we know that a considerable force is required to achieve dissociation of a well impacted head, with cited values including 3003 ± 623 N [ 20 ] and 427 kg [ 21 ]. Adequate impaction of the head-neck interface is achieved by a strong blow with a 0.5 kg mallet and a femoral head driver, in combination with the cyclic impaction loading in the normal activities of daily living.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In head-neck dissociation, postulated mechanisms include strong distraction forces caused by the inferior edge of the femoral head becoming caught on the rim of the acetabular component during reduction of a dislocation [ 19 ] and excessive external rotation in the presence of a constrained liner, in which the elevated liner would act as a fulcrum at the head and neck junction [ 6 ]. However, we know that a considerable force is required to achieve dissociation of a well impacted head, with cited values including 3003 ± 623 N [ 20 ] and 427 kg [ 21 ]. Adequate impaction of the head-neck interface is achieved by a strong blow with a 0.5 kg mallet and a femoral head driver, in combination with the cyclic impaction loading in the normal activities of daily living.…”
Section: Discussionmentioning
confidence: 99%
“…Another theory is that “pumping phenomenon,” a mechanical engineering term, may be responsible for rising air pressure in the inner head, giving rise to an unlocked tapered neck where there is air trapping between the inner head and tapered stem. Smaller forces are required for dissociation as sealed air pushes back on the neck and unlocks the taper mechanism of the inner head, causing separation [ 21 ]. However, in the case presented here, we see the complication arise in a nontraumatic scenario, after 10 years of full weight bearing, which makes the possibilities of high distraction forces and a pumping phenomenon seem unlikely.…”
Section: Discussionmentioning
confidence: 99%
“…However, there are limited reports on acute spontaneous dissociation of head and neck at the taper junction in bipolar hemiarthroplasty. A previous case reported inner femoral head disassembly from the stem-neck taper junction which occurred after revision of the head of a bipolar hip prosthesis [6] . The present study reports an acute disassembly of a primary bipolar hemiarthroplasty at the femoral head and stem-neck taper junction in a patient with nerve palsy.…”
Section: Introductionmentioning
confidence: 99%
“…These marketed advantages have, however, come with increased risks and complications [4,15,27,44,70]. Unfortunately, adding another metal taper junction may increase the burden of corrosion debris and the risk of local tissue reactions as well as serve as a possible weak link that can increase the risk of a catastrophic failure [4,15,27,44,70]. As with any additional technological advancement in implant designs, both alternative bearings and increased modularity add cost to the implants in most cases.…”
Section: Introductionmentioning
confidence: 99%