2019
DOI: 10.1049/iet-com.2018.6008
|View full text |Cite
|
Sign up to set email alerts
|

Directional mobile charging method for mine Internet of things

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 20 publications
(24 reference statements)
0
7
0
Order By: Relevance
“…KMEC‐Charging adopts a cluster‐first route‐second strategy to charge the sensor nodes efficiently under the constraint of MC capacity; the cluster‐first strategy shares common features with SCTD‐Charging of choose candidate charging nodes. The simulation parameters and their default settings are listed in Table 1 [27–29]. Event distortion : Figure 10 shows the effect of the number of active nodes on the distortion under different values of distance parameter of 10, 50, 100, 500, 1000, 5000 and 10,000.…”
Section: Performance Analysismentioning
confidence: 99%
“…KMEC‐Charging adopts a cluster‐first route‐second strategy to charge the sensor nodes efficiently under the constraint of MC capacity; the cluster‐first strategy shares common features with SCTD‐Charging of choose candidate charging nodes. The simulation parameters and their default settings are listed in Table 1 [27–29]. Event distortion : Figure 10 shows the effect of the number of active nodes on the distortion under different values of distance parameter of 10, 50, 100, 500, 1000, 5000 and 10,000.…”
Section: Performance Analysismentioning
confidence: 99%
“…Taking Fig. 4 as an example [9], Sk represents Nodek. Assuming that the MC moves in the middle line of the roadway, and O is the projection of Sk on the vertical plane of the MC (the plane perpendicular to the middle line of the roadway), ||OSi=w/2, where w is the width of the roadway.…”
Section: Hybrid Charging Of Controlled MC and Opportunistic Mcmentioning
confidence: 99%
“…The default settings of the parameters are as follows [7, 9]: GMC=8thinmathspacedBi, Grfalse(ifalse)=2thinmathspacedBi, η=0.125, PMC=5thinmathspacenormalW, λ=0.158, v=0.5thinmathspacenormalm/normals, Lp=2thinmathspacedB, β=0.2316. Since it is the charging service provided by the opportunistic MC that lays the basis for C&O charging, we first evaluate the charging ability of opportunistic MC.…”
Section: Performance Simulationsmentioning
confidence: 99%
See 2 more Smart Citations