2019
DOI: 10.1161/circep.118.006801
|View full text |Cite
|
Sign up to set email alerts
|

Direct Visualization of the His Bundle Pacing Lead Placement by 3-Dimensional Electroanatomic Mapping

Abstract: Background: His bundle pacing (HBP) remains technically challenging and is currently guided by electrograms and 2-dimensional fluoroscopy. Our objective was to describe a new technique for HBP directly guided by electroanatomic mapping (EAM). Methods: Twenty-eight patients were included. The atrioventricular septum was mapped via EAM, and His bundle (HB) electrograms, selective, and nonselective HB capture sites were tagged. Pacing leads were connected … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
29
1
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 24 publications
(32 citation statements)
references
References 21 publications
1
29
1
1
Order By: Relevance
“…In most patients, electroanatomic mapping of the interatrial septum using the EnSite Precision system (Abbott, Des Plaines, IL) was performed in order to characterize the HB region and ultimately to visualize the lead tip during lead placement ( Supplementary Figure 1). 25 Leads evaluated in this series included the 5.8F model 7742 Ingevity (Boston Scientific), which has a 1.8-mm (4.5-mm 2 ) extendable-retractable, electrically active helix; the 5.1F model 4471 FINELINE II (Boston Scientific), which has a 1.6-mm fixed, nonconductive helix extending from a 5-mm 2 cylindrical electrode situated at the end of the lead body; and the SelectSecure 3830 (Medtronic PLC), which has a 1.8-mm electrically active helical electrode (Figure 3). All leads are steroid eluting, although the location of the steroid differs.…”
Section: Implant Technique: Access Mapping Catheters and Leadsmentioning
confidence: 99%
“…In most patients, electroanatomic mapping of the interatrial septum using the EnSite Precision system (Abbott, Des Plaines, IL) was performed in order to characterize the HB region and ultimately to visualize the lead tip during lead placement ( Supplementary Figure 1). 25 Leads evaluated in this series included the 5.8F model 7742 Ingevity (Boston Scientific), which has a 1.8-mm (4.5-mm 2 ) extendable-retractable, electrically active helix; the 5.1F model 4471 FINELINE II (Boston Scientific), which has a 1.6-mm fixed, nonconductive helix extending from a 5-mm 2 cylindrical electrode situated at the end of the lead body; and the SelectSecure 3830 (Medtronic PLC), which has a 1.8-mm electrically active helical electrode (Figure 3). All leads are steroid eluting, although the location of the steroid differs.…”
Section: Implant Technique: Access Mapping Catheters and Leadsmentioning
confidence: 99%
“…Recent reports have described using 3‐D mapping to implant HBP leads 13–15 . Orlov et al 16 described a series of 25 patients for whom HBP lead was implanted with fluoroscopy time averaging 8.6 minutes using Ensite system. Similarly, in the present study, the fluoroscopy time was 6.1 ± 3.2 minutes mainly for HBP and RV pacing implantation and AVN ablation with CARTO system.…”
Section: Discussionmentioning
confidence: 99%
“…The leads may be dislocated after fixation. So we performed HBP and AVN ablation in the same session, 15,16,18 with the RV pacing for standby application, which is relatively safer than only HBP without RV lead. It is of a very low probability to occur that HBP and RV both dislodge.…”
Section: Discussionmentioning
confidence: 99%
“…2 Since then, HBP has evolved into an effective and widely accepted procedure, 3,4 leading to clinical benefits superior to right ventricular (RV) pacing. [5][6][7][8] While HBP success has been reported as high as 93%-96%, 9 there is an incomplete understanding of the optimal pacing location and related anatomical characteristics. Currently, the target area is identified using either a multipolar electrode catheter or the pacing lead itself to perform point-by-point electrogram mapping.…”
Section: Introductionmentioning
confidence: 99%
“…Implantation techniques for these leads were recently described. 7 In brief, coronary sinus guiding sheaths (Acuity Pro CS-EH-S-R; Boston Scientific) were used to direct the lead to the HB capture area. Lead placement was assisted by EAM to generate a 3D map of the AV septum and surrounding areas.…”
Section: Introductionmentioning
confidence: 99%