1995
DOI: 10.1016/0021-9673(94)00890-l
|View full text |Cite
|
Sign up to set email alerts
|

Direct separation of carboxylic acid enantiomers by high-performance liquid chromatography with amide and urea derivatives bonded to silica gel as chiral stationary phases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
1

Year Published

1998
1998
2022
2022

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 50 publications
(5 citation statements)
references
References 10 publications
0
4
0
1
Order By: Relevance
“…In the past decades, several chromatographic resolutions of chrysanthemic acid and its analogues have been reported. For example, the direct resolutions of chrysanthemic acid have been achieved on the brush‐type CSPs derived from (+)‐terguride alkaloid,2, 3 amino acids,4 tripeptide esters,5 and cinchona alkaloid derivatives 6. Recently, the effectiveness of the polysaccharide‐based CSPs, Chiralcel OD, Chiralcel OF, and Chiralpak AS, for the resolution of the underivatized chrysanthemic acid has been reported 7, 8.…”
Section: Introductionmentioning
confidence: 99%
“…In the past decades, several chromatographic resolutions of chrysanthemic acid and its analogues have been reported. For example, the direct resolutions of chrysanthemic acid have been achieved on the brush‐type CSPs derived from (+)‐terguride alkaloid,2, 3 amino acids,4 tripeptide esters,5 and cinchona alkaloid derivatives 6. Recently, the effectiveness of the polysaccharide‐based CSPs, Chiralcel OD, Chiralcel OF, and Chiralpak AS, for the resolution of the underivatized chrysanthemic acid has been reported 7, 8.…”
Section: Introductionmentioning
confidence: 99%
“…Consequently, we were delighted to find that a chiral column loaded with ( R )-1-naphthylglycine succeeded in separating the two stereoisomers of (+) 300 /(−) 300 - 10d ( Fig. 4 B ) ( 28 ). Preliminary theoretical investigations on the rotational barrier indicated the presence of a high barrier of >30 kcal ⋅ mol −1 .…”
Section: Resultsmentioning
confidence: 99%
“…However, CE has precision problem in the migration times with runs compared to HPLC and GC. Many chiral stationary phases available for direct enantioseparation of profens by HPLC require prior derivatization [10][11][12]. In contrast, chiral mobile phase additives provide direct enantioseparation of profens as diastereomeric ion-pairs without derivatization [13,14].…”
Section: Introductionmentioning
confidence: 99%