1999
DOI: 10.1016/s0584-8547(99)00020-8
|View full text |Cite
|
Sign up to set email alerts
|

Direct sample insertion for inductively coupled plasma spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0

Year Published

2000
2000
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(13 citation statements)
references
References 72 publications
0
13
0
Order By: Relevance
“…Finally, the even more transient signal than with ETV further limits the number of analytes that can be determined by ICP-QMS or ICP-SFMS. For more details on DSI, the reader is referred to a review (Sing, 1999) and a book chapter (Karanassios & Wood, 2000).…”
Section: Environmental Analysis By Icp-msmentioning
confidence: 99%
“…Finally, the even more transient signal than with ETV further limits the number of analytes that can be determined by ICP-QMS or ICP-SFMS. For more details on DSI, the reader is referred to a review (Sing, 1999) and a book chapter (Karanassios & Wood, 2000).…”
Section: Environmental Analysis By Icp-msmentioning
confidence: 99%
“…A wide variety of techniques have been developed for the introduction of solids, liquids and gases into ICP-MS instrumentation (Campbell 1992, Jarvis 1992, Günther et al 1999, Sing 1999, Kántor 2001, Russo et al 2002, Mora et al 2003, Günther and Hattendorf 2005, Nakahara 2005). However, discussion in this review will be limited to liquids, the most common sample types analysed by ICP-MS.…”
Section: Sample Introduction Into the Plasmamentioning
confidence: 99%
“…Since the technique was first introduced by Salin and Horlick in 1979, 1 there has been continuous efforts concerning DSI development in the past two decades. 2,3 DSI-ICP is similar to graphite-furnace atomic absorption spectrometry (GF-AAS) in several aspects. Firstly, graphite sample probes are commonly used in DSI-ICP, 3 although tungsten wire loops 4 and metal sample cups 5,6 have also been reported.…”
Section: Direct Sample Insertion (Dsi) Is An Alternative Sample Intromentioning
confidence: 99%
“…2,3 DSI-ICP is similar to graphite-furnace atomic absorption spectrometry (GF-AAS) in several aspects. Firstly, graphite sample probes are commonly used in DSI-ICP, 3 although tungsten wire loops 4 and metal sample cups 5,6 have also been reported. Secondly, because the sample is thermally evaporated from the graphite probe, the analyte and matrix vaporization behavior and pattern are similar for GF-AAS and DSI-ICP.…”
Section: Direct Sample Insertion (Dsi) Is An Alternative Sample Intromentioning
confidence: 99%