2017
DOI: 10.1016/j.synthmet.2017.09.009
|View full text |Cite
|
Sign up to set email alerts
|

Direct, one-step synthesis of molybdenum blue using an electrochemical method, and characterization studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
20
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 34 publications
(23 citation statements)
references
References 22 publications
3
20
0
Order By: Relevance
“…Because the conductivity of graphene layers higher than that of PGE, Rct values were lower in C‐GPGEs and Cl‐GO than PGE . R SEI values were also lower in modified electrodes than PGE indicating formation of more conductive graphene layers on the PGE surface during the modification process (Table ) . The capacitances of modified electrodes were increased with the modification of chlorine doping and forming graphene according to the CPE1 and CPE2 which were higher in Cl‐GPGEs and Cl‐GO than PGE .…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Because the conductivity of graphene layers higher than that of PGE, Rct values were lower in C‐GPGEs and Cl‐GO than PGE . R SEI values were also lower in modified electrodes than PGE indicating formation of more conductive graphene layers on the PGE surface during the modification process (Table ) . The capacitances of modified electrodes were increased with the modification of chlorine doping and forming graphene according to the CPE1 and CPE2 which were higher in Cl‐GPGEs and Cl‐GO than PGE .…”
Section: Resultsmentioning
confidence: 99%
“…Rct values, which were caused from Faradaic reactions, were determined as 0.421, 0.797, 0.659, 0.604, and 4.760 Ω for Cl‐GPGE1, Cl‐GPGE2, Cl‐GPGE3, Cl‐GO, and PGE, respectively (Table ). Because the conductivity of graphene layers higher than that of PGE, Rct values were lower in C‐GPGEs and Cl‐GO than PGE . R SEI values were also lower in modified electrodes than PGE indicating formation of more conductive graphene layers on the PGE surface during the modification process (Table ) .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…One of the most important factors affecting the practical use of high-performance electrochemical sensors and biosensors is selectivity [58,59]. The interaction often occurs under physiological conditions created by the presence of ascorbic acid (AA, 1 mM), uric acid (UA, 1 mM), glucose (G, 1 mM), and dopamine (DA, 1 mM) [18].…”
Section: Interference Studymentioning
confidence: 99%
“…The electrochemical performance showed that the TBA + /PGE exhibited remarkable electrocatalytic activity against NADH in human blood serums and this demonstrate that the novel TBA + /PGE can be used for electrochemical sensor and biosensor applications. All of the electrochemical measurements were carried out with a three-electrode system using the pencil graphite electrode (PGE) (Tombow HB, 0.5 mm) as the working electrode, the Ag/AgCl electrode as the reference electrode, and the Pt wire as the counter electrode [38].…”
Section: Introductionmentioning
confidence: 99%