Direct Observation of Perovskite Photodetector Performance Enhancement by Atomically Thin Interface Engineering

Abstract: Lead trihalide perovskites have been integrated with atomically thin WS2 and served as absorption layers to improve photoresponsivity in photodetectors. The combination of perovskites and two-dimensional (2D) transition-metal dichalcogenide (TMDC) materials provides the platform to study light–matter interactions and charge transfer mechanisms in optoelectronic devices. Herein, conductive and photoconductive atomic force microscopy were used to image the dark current and photocurrent generated in WS2/CH3NH3PbI… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

4
36
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 26 publications
(40 citation statements)
references
References 55 publications
(70 reference statements)
4
36
0
Order By: Relevance
“…X-ray diffraction (XRD) measurements were also performed and provided further evidence of the presence of the CdS and MAPbI3 when deposited on ITO ( Figure 1c). The diffraction peaks of CdS indium tin oxide (ITO) (transparent electrode), 28 and MAPbI3. 42,43 are indicated by the yellow, green and blue bars, 41 respectively.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…X-ray diffraction (XRD) measurements were also performed and provided further evidence of the presence of the CdS and MAPbI3 when deposited on ITO ( Figure 1c). The diffraction peaks of CdS indium tin oxide (ITO) (transparent electrode), 28 and MAPbI3. 42,43 are indicated by the yellow, green and blue bars, 41 respectively.…”
Section: Resultsmentioning
confidence: 99%
“…The relatively high η is likely attributable to non-idealities such as defects at the perovskite surface. 28 Figure 7d were also studied by PC-AFM in order to compare the charge transport with photocurrent characteristics. Figure S12 shows the photocurrent maps obtained at different applied sample potentials measured under 405 nm laser illumination.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The PC-AFM measurements are conducted using a Pt-Ir-coated conductive AFM tip. Bias voltages are applied on the conductive ITO substrate and the Pt-Ir tip is held at ground [49]. For the PC-AFM technique, topography and photocurrent of MAPbI 3 can be recorded simultaneously.…”
Section: Resultsmentioning
confidence: 99%
“…Responsivity ( R ) is an important parameter to assess the performance of a photodetector. R can be calculated using the following equation: R=IpIdPA where I p , I d , P , and A are the photocurrent, dark current, incident light intensity, and active area of the device, respectively [49]. The responsivities of all devices at a 5 V bias voltage are summarized in Table 2.…”
Section: Resultsmentioning
confidence: 99%