2000
DOI: 10.1002/(sici)1096-9888(200001)35:1<50::aid-jms912>3.0.co;2-j
|View full text |Cite
|
Sign up to set email alerts
|

Direct measurement of urinary testosterone and epitestosterone conjugates using high-performance liquid chromatography/tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
70
0

Year Published

2000
2000
2014
2014

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 87 publications
(73 citation statements)
references
References 33 publications
2
70
0
Order By: Relevance
“…In addition, this method has a good extraction recovery rate for both steroids allowing for accurate concentration determination by the use of the internal standard, stanozolol-D3. Whilst methods have been described for the detection of testosterone and epitestosterone in humans [17,18], this method provides deconjugation and extraction procedures affording detection of testosterone and epitestosterone concentrations in rat serum and urine. This method could be used in future research to investigate testosterone and epitestosterone metabolism in vivo.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, this method has a good extraction recovery rate for both steroids allowing for accurate concentration determination by the use of the internal standard, stanozolol-D3. Whilst methods have been described for the detection of testosterone and epitestosterone in humans [17,18], this method provides deconjugation and extraction procedures affording detection of testosterone and epitestosterone concentrations in rat serum and urine. This method could be used in future research to investigate testosterone and epitestosterone metabolism in vivo.…”
Section: Discussionmentioning
confidence: 99%
“…Previous methods have been reported but with limitations such as validated applications to either urine [17][18][19][20] or serum [21] only; and with an extraction method taking greater than 1 hour [21]. In comparison, the new method benefits from improved resolution [19] Table 7: Serum testosterone and epitestosterone in rats after the fourth week of sample collection ± SEM of triplicate injections.…”
Section: Application Of Methods For Determination Of Testosterone and mentioning
confidence: 99%
“…The quadrupole mass filter is widely used as a single stage analyzer, triple stage analyzer, and hybrid type of quadrupole and TOF mass analyzer. Mass analyzers of the single and triple-stage types have played roles in the quantitative study of drug metabolism 69 and endogenous biologically active substances [72][73][74] and in the qualitative study of combinatorial chemistry. [146][147][148][149] These mass analyzers coupled with ESI, APCI and TSP are favorable for combinations with liquid separation techniques, such as HPLC and capillary electrophoresis (CE).…”
Section: ·1 Quadrupole Mass Spectrometermentioning
confidence: 99%
“…Even if it is a drug metabolite, besides stereoisomers, unstable polar metabolites, such as glucuronates and sulfates, may easily produce fragment ions having the same m/z ratio as the drug itself at the first mass analyzer. 174 In addition, prodrugs containing methyl esters and methylated metabolites from the active form, which are completely different compounds, but have the same m/z ratio as a molecular ion, often show a similar MS/MS pattern. Therefore, those isomers and metabolites must be separated by chromatography before MS/MS detection.…”
Section: ·3 Endogenous Active Substancesmentioning
confidence: 99%
See 1 more Smart Citation