2018
DOI: 10.1039/c8ja00031j
|View full text |Cite
|
Sign up to set email alerts
|

Direct measurement of multi-elements in high matrix samples with a flow injection ICP-MS: application to the extendedEmiliania huxleyiRedfield ratio

Abstract: Based on our novel ICP-MS method, we find that the metalloproteins are a better indicator of metal requirements of phytoplankton compared with whole cell metal quotas.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
30
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 20 publications
(30 citation statements)
references
References 53 publications
0
30
0
Order By: Relevance
“…We did not observe difference in growth rate in cultures with equivalent [Fe′] (7500 pmol L −1 ) but with varying [EDTA]; cultures with 12 µmol L −1 EDTA, relative to regular SCM media with 7.5 µmol L −1 [EDTA], did not produce an inhibitory effect (data not shown). [Fe′] in cultures was calculated using Visual Minteq software [33], including background Fe contamination of 50 nmol L −1 from basal SCM medium with included macronutrients and vitamins but without added trace metals, determined using inductively coupled plasma mass spectrometry [34]. Cultures were acclimated to metal concentrations stated by transferring cultures consecutively into new media until growth rates did not vary with statistical significance (ANOVA, p < 0.05).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…We did not observe difference in growth rate in cultures with equivalent [Fe′] (7500 pmol L −1 ) but with varying [EDTA]; cultures with 12 µmol L −1 EDTA, relative to regular SCM media with 7.5 µmol L −1 [EDTA], did not produce an inhibitory effect (data not shown). [Fe′] in cultures was calculated using Visual Minteq software [33], including background Fe contamination of 50 nmol L −1 from basal SCM medium with included macronutrients and vitamins but without added trace metals, determined using inductively coupled plasma mass spectrometry [34]. Cultures were acclimated to metal concentrations stated by transferring cultures consecutively into new media until growth rates did not vary with statistical significance (ANOVA, p < 0.05).…”
Section: Methodsmentioning
confidence: 99%
“…HNO 3 was added to reflux for an hour to resuspend the dried samples. 56 Fe and 31 P concentrations were determined using a Quadrupole ICP-MS Perkin Elmer NexION 350 with Elemental Scientific Flow Injection Auto-sampler (FIAS) in a method optimised for high salt matrixes [34].…”
Section: Methodsmentioning
confidence: 99%
“…The cells were then washed two times with chelexed synthetic ocean water (made according to the methods of Morel et al ) and one time with Tris buffer (pH = 8.2) in order to remove the loosely bound metals on cell surfaces. The pellets were then digested in HNO 3 and H 2 O 2 and metal contents were measured using the ICP‐MS, according to the methods of Zhang et al ().…”
Section: Methodsmentioning
confidence: 99%
“…Last, the pellet containing the MRG was digested with in‐house distilled HNO 3 and ultrapure H 2 O 2 . The respective solutions containing the protein, CD, and MRG fractions were then measured on the ICP‐MS, again, according to the methods of Zhang et al ().…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation