Direct measurement of high-density lipoprotein cholesterol in serum with polyethylene glycol-modified enzymes and sulfated alpha-cyclodextrin

Abstract: We have developed an automated method for measuring high-density lipoprotein (HDL)-cholesterol in serum without prior separation, using polyethylene glycol (PEG)-modified enzymes and sulfated alpha-cyclodextrin. When cholesterol esterase and cholesterol oxidase enzymes were modified with PEG, they showed selective catalytic activities towards lipoprotein fractions, with the reactivity increasing in the order: low-density lipoprotein < very-low-density lipoprotein approximately chylomicron < HDL. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
110
0
1

Year Published

1999
1999
2018
2018

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 405 publications
(120 citation statements)
references
References 0 publications
1
110
0
1
Order By: Relevance
“…Total cholesterol (TC), HDL cholesterol (HDL-C) and triglycerides (Tg) were measured enzymatically as described previously. [17][18][19] LDL cholesterol (LDL-C) was calculated according to the Friedewald formula. In cases of severe hypertriglyceridaemia (Tg ≥ 400 mg/dL), LDL-C was measured directly.…”
Section: Clinical Risk Factors and Laboratory Measurementsmentioning
confidence: 99%
“…Total cholesterol (TC), HDL cholesterol (HDL-C) and triglycerides (Tg) were measured enzymatically as described previously. [17][18][19] LDL cholesterol (LDL-C) was calculated according to the Friedewald formula. In cases of severe hypertriglyceridaemia (Tg ≥ 400 mg/dL), LDL-C was measured directly.…”
Section: Clinical Risk Factors and Laboratory Measurementsmentioning
confidence: 99%
“…Half of the plasma was then stored at −70°C for evaluating pre-thrombotic status, including t-PA/PAI-I (ratio of tissue type plasminogen activator to plasminogen activator inhibitor) by enzyme-linked immunosorbent assay technique using corresponding mouse monoclonal anti-human antibodies (Manufacturer's Datasheet, XITANG Biotechnology, Shanghai, China) and APTT (activated partial thromboplatin time) by an automatic blood coagulation analysis device (SysmexCA-50, Japan). The other half was stored at − 70°C for evaluating lipid transportation, including LDL/HDL (ratio of low-density lipoprotein cholesterol to high-density lipoprotein cholesterol) [12,13].…”
Section: Hematological Examinationmentioning
confidence: 99%
“…One was a conventional reagent kit (Lot No. 304AAK: Kyowa Medex Co., Ltd., Osaka, Japan) that selectively measured only HDL-cholesterol using polyethylene glycol and cyclodextrin sulfate together with chemically modified cholesterol oxidase and esterase, as described previously (5). The other was the new reagent kit (Lot No.…”
Section: Homogeneous Hdl-c Assaysmentioning
confidence: 99%
“…Conventionally, it had been measured by the UC method or by the precipitation method. However, homogeneous HDL-cholesterol assay without pretreatment has recently been developed and has been rapidly popularized (4)(5)(6)(7)(8)(9). Several homogeneous HDL-cholesterol assays, based on different principles, are available commercially, but they all give inaccurate results when high-TG samples are tested (10,11).…”
Section: Introductionmentioning