Abstract:This study presents a practical method for high-precision Fe isotope determination without column chromatography purification for iron-dominated mineral samples using multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS). A series of comparable...
“…JMC Fe (δ 56 Fe = 0.41 ± 0.12‰) 31 was used as an unknown sample for quality control. The Fe isotope ratios of NWU-Fe and IGGCAS-Fe are δ 56 Fe = 0.70 ± 0.03‰ 32 and δ 56 Fe = 0.658 ± 0.027‰ relative to the reference material IRMM-014, respectively. Furthermore, IGGCAS-Fe and JMC Fe have also been used to evaluate the precision of the method over a 6 month period.…”
Here we present an analytical method for Fe isotopic measurements in low resolution mode, using a Nu Sapphire collision cell-equipped multi-collector inductively coupled plasma mass spectrometer by standard-sample bracketing. High...
“…JMC Fe (δ 56 Fe = 0.41 ± 0.12‰) 31 was used as an unknown sample for quality control. The Fe isotope ratios of NWU-Fe and IGGCAS-Fe are δ 56 Fe = 0.70 ± 0.03‰ 32 and δ 56 Fe = 0.658 ± 0.027‰ relative to the reference material IRMM-014, respectively. Furthermore, IGGCAS-Fe and JMC Fe have also been used to evaluate the precision of the method over a 6 month period.…”
Here we present an analytical method for Fe isotopic measurements in low resolution mode, using a Nu Sapphire collision cell-equipped multi-collector inductively coupled plasma mass spectrometer by standard-sample bracketing. High...
“…52 Cr and 53 Cr were monitored to estimate the Cr content and the 54 Cr isobaric interference on 54 Fe, and 52 Cr ( 54 Cr/ 52 Cr = 0.028222) was used to subtract the interference of 54 Cr on 54 Fe isotopes. 20 The mass resolution was set at high resolution. For laser ablation measurements, the 206 nm laser wavelength was used.…”
Section: In Situ Fe Isotope Analysismentioning
confidence: 99%
“…The sample was analyzed at the SKLCD, Northwest University, using the method of Chen et al (2022). 20 Approximately 10 mg of magnetite powder was weighed in a 15 mL PFA beaker. The samples were dissolved in a 0.5 mL concentrated aqua regia (HCl : HNO 3 = 3 : 1, v/v) mixture at 80 °C for 12 h under closed conditions.…”
Section: Solution Fe Isotope Analysismentioning
confidence: 99%
“…The SSB method was used for mass bias correction, and the NWU-Fe pure Fe solution was used as the bracketing standard. 20 Alfa-Fe1 was used as the unknown sample for data quality control. The measured d 56 Fe IRMM-014 of alfa-Fe1 is 0.54 ± 0.04& (2SD, n = 22) (Table 3), which was consistent with the reported value (0.53 ± 0.04&) within 2SD uncertainty.…”
A high-temperature and high-pressure sintering method was used to prepare magnetite (MtFe-1), which can be used as a matrix-matched bracketing standard for Fe isotope analysis of natural magnetite using LA-MC-ICP-MS.
“…The potential for Fe isotopes to be measured without chromatographic purification of iron-rich samples was investigated by Chen et al 178 Their study measured 40 Fe-based RMs using MC-ICP-MS. Following dissolution using HNO 3 and aqua regia , aliquots of these samples were purified using AG1-X8 cation exchange.…”
This review covers advances in atomic spectrometric techniques, including atomic emission, absorption, fluorescence and mass spectrometry. Material on speciation and coupled techniques is not covered as this is included in a separate ASU review.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.