2013
DOI: 10.1016/j.mimet.2012.12.016
|View full text |Cite
|
Sign up to set email alerts
|

Direct identification of bacteria causing urinary tract infections by combining matrix-assisted laser desorption ionization-time of flight mass spectrometry with UF-1000i urine flow cytometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
99
0
2

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 93 publications
(106 citation statements)
references
References 21 publications
5
99
0
2
Order By: Relevance
“…One limitation is the large amount of protein necessary to obtain reliable profiles. Therefore, as suggested by Wang et al (11), samples need to be preselected depending on the bacterial load. Another useful algorithm for the rapid diagnosis of UTIs is presented by Burillo et al (20), who combined Gram stain with mass spectrometry.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…One limitation is the large amount of protein necessary to obtain reliable profiles. Therefore, as suggested by Wang et al (11), samples need to be preselected depending on the bacterial load. Another useful algorithm for the rapid diagnosis of UTIs is presented by Burillo et al (20), who combined Gram stain with mass spectrometry.…”
Section: Discussionmentioning
confidence: 99%
“…Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been suggested as a fast and reliable method for bacterial identification (8). This methodology has successfully been used for the rapid identification of microorganisms, both from culture plates and positive blood cultures, and also on other clinical samples, such as those from urine (9)(10)(11)(12)(13)(14). A biomarker capable of predicting the ability of MALDI-TOF MS to identify microorganisms directly from clinical samples would be useful to improve the diagnostic procedure, reducing costs and time.…”
mentioning
confidence: 99%
“…Urine flow cytometry may be used to screen out negative urines, with MALDI-TOF MS reserved to test the positive urine samples (55,56 ). Urine must be processed before MALDI-TOF MS testing.…”
Section: Direct Testing Of Clinical Samplesmentioning
confidence: 99%
“…Algunos estudios han evaluado el desempeño del MALDI-TOF MS para la identificación directa de microorganismos en muestras de orina, en conjunción con el uso de pruebas de tamización iniciales para determinar la positividad de la muestra. En el estudio de Wang y colaboradores 42 , se realizó la comparación entre los resultados de los métodos convencionales de urocultivo, con MALDI-TOF MS con un espectrómetro de masas Auto-flex III (Bruker Daltonics Inc.) acoplado a citometría de flujo (UF-1000i) para tamizar las orinas positivas de individuos con sintomatología de infección urinaria. Los resultados de MALDI-TOF MS fueron consistentes con los obtenidos por los métodos convencionales en 1373 de las 1456 muestras analizadas (94,3%), incluyendo 982 muestras negativas.…”
Section: Orinaunclassified