2017
DOI: 10.1016/j.aca.2017.09.022
|View full text |Cite
|
Sign up to set email alerts
|

Direct Electrochemical DNA Sensor based on a new redox oligomer modified with ferrocene and carboxylic acid: Application to the detection of Mycobacterium tuberculosis mutant strain

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
2
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 28 publications
(8 citation statements)
references
References 36 publications
0
8
0
Order By: Relevance
“…The poly(p-phenylene) (PPP) modified with ferrocene groups (Fc), as side chains (Fc-PPP) has been synthesized and characterized by NMR and FTIR as described previously [30], the poly(p-phenylene) (PPP) modified with ferrocene groups (Fc) and carboxylic acids (Ac) as functional groups in side chains (Fc-ac-PPP) has been prepared by the alkaline hydrolysis of the Fc-PPP and confirmed by FTIR spectra as described previously [31].…”
Section: Reagentsmentioning
confidence: 99%
See 1 more Smart Citation
“…The poly(p-phenylene) (PPP) modified with ferrocene groups (Fc), as side chains (Fc-PPP) has been synthesized and characterized by NMR and FTIR as described previously [30], the poly(p-phenylene) (PPP) modified with ferrocene groups (Fc) and carboxylic acids (Ac) as functional groups in side chains (Fc-ac-PPP) has been prepared by the alkaline hydrolysis of the Fc-PPP and confirmed by FTIR spectra as described previously [31].…”
Section: Reagentsmentioning
confidence: 99%
“…The Fc-ac-PPP and Fc-PPP solutions have been prepared by dispersing 5 mg of each polymer in 1.5 mL CHCl 3 , and ultra-sonicated for 30 min. The gold surface, after polishing steps, was dropped with an optimum amount of 5 µl Fc-ac-PPP or Fc-PPP solution as optimized previously [31] followed by a drying step under ambient temperature during 30 min. After the evaporation of the volatile solvent, the modified gold surface was then rinsed with distilled water to remove non-attached molecules.…”
Section: Surface Preparation and Modificationmentioning
confidence: 99%
“…The membranes based on the nanocomposite CRGO/Fc-ac-PPP with different mass ratio were characterized using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) to underline the best ratio for sensor application. The polymer intituled "poly(para-phenylene)" modified with ferrocene and an acidic group in its backbone (Fc-ac-PPP) has been synthesized and characterized according to the previously reported procedure [26,27]. Gold electrode, graphene oxide (GO), dimethylformamide (DMF), ethanol, phosphate buffer solution (PBS tablets), AA, DA, UA, potassium ferrocyanide ([Fe(CN)6] 3-/4-), ruthenium hexamine ([Ru(NH3)6] 2+/3+ ) and urine samples were purchased from Sigma Aldrich (France).…”
Section: Nanocomposite Formation Crgo/fc-ac-pppmentioning
confidence: 99%
“…This outcome is attributed to the large surface area of silica nanospheres (SiNSs) for DNA immobilisation sites. When compared with DNA hybridisation indicator that employed ferrocenium compounds 9,10 , the biosensor developed here has comparable LOD, but it did not require any procedure for ferrocene labelling, i.e. chemical attachment of ferrocene compounds to the DNA.…”
Section: The Percentage Of Hypochromicity Was Calculated Following Eqmentioning
confidence: 99%
“…Sato and Takenaka 8 studied electrochemical DNA detection using ferrocenylnaphthalenediimide. In most of the reported work involving ferrocene/Fe(III) compounds of DNA hybridisation indicator, they were used as labels that needed to be chemically attached to the DNA probes to detect a hybridisation event 9,10 .…”
Section: Introductionmentioning
confidence: 99%