1983
DOI: 10.1002/elps.1150040205
|View full text |Cite
|
Sign up to set email alerts
|

Direct digital imaging of radio‐labeled two‐dimensional gel beta emissions using micro‐channel plate image enhancement

Abstract: Linus ~a u~i n gInstitute of Science and gel beta emissions using micro-channel plate image enhancement* Medicine, Palo Alto, CAThe use of autoradiography to record the distribution of radio-labels such as tritium or 35S in two-dimensional (2-D) gels has well known deficiencies: the film requires long exposures, has a nonlinear response curve, and has a restricted dynamic range. Autofluorography can improve upon each of these problems but only at the cost of resolution and quantitative accuracy. This paper dem… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

1
3
0

Year Published

1983
1983
1999
1999

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 16 publications
1
3
0
Order By: Relevance
“…A review of the electrophoresis literature shows that our imaging modality is similar to earlier work published in two papers in the mid-nineteen eighties [10,11]. Burbeck et al [10] reported an MCP-based detector of 40 mm diameter having a spatial resolution (200 mm) much poorer than either of our current detectors [7].…”
Section: Microchannel Plate Detectorsupporting
confidence: 54%
See 2 more Smart Citations
“…A review of the electrophoresis literature shows that our imaging modality is similar to earlier work published in two papers in the mid-nineteen eighties [10,11]. Burbeck et al [10] reported an MCP-based detector of 40 mm diameter having a spatial resolution (200 mm) much poorer than either of our current detectors [7].…”
Section: Microchannel Plate Detectorsupporting
confidence: 54%
“…Burbeck et al [10] reported an MCP-based detector of 40 mm diameter having a spatial resolution (200 mm) much poorer than either of our current detectors [7]. While their system was capable of imaging tritiated labeled gels, neither of their papers gave measurements of the efficiency or linearity for tritium.…”
Section: Microchannel Plate Detectormentioning
confidence: 89%
See 1 more Smart Citation
“…When such numbers of proteins are separated, as they usually are in biological work, their quantification by automated procedures is almost a necessity. The first attempts at developing automated quantification procedures were published in 1978 (2)(3)(4), and several laboratories are now in various stages of developing their own such procedures (5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20). The potential of a fully computerized system is outlined in ref 20, along with a short review of the field.…”
mentioning
confidence: 99%