2004
DOI: 10.1039/b307780m
|View full text |Cite
|
Sign up to set email alerts
|

Direct determination of trace impurities in niobium pentaoxide solid powder with slurry sampling fluorination assisted electrothermal vaporization inductively coupled plasma mass spectrometry

Abstract: A method of fluorination assisted electrothermal vaporization inductively coupled plasma mass spectrometry (FETV-ICP-MS) was developed to directly determine the trace impurities in niobium pentaoxide solid powder in which a poly(tetrafluoroethylene) (PTFE) emulsion was used as fluorinating modifier to promote the vaporization of refractory elements from a graphite furnace and to avoid the formation of thermally stable carbides. The solid sample was introduced into the graphite furnace in the form of slurry wit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
22
0

Year Published

2005
2005
2015
2015

Publication Types

Select...
8

Relationship

7
1

Authors

Journals

citations
Cited by 38 publications
(22 citation statements)
references
References 26 publications
0
22
0
Order By: Relevance
“…Details on the modification of the graphite furnace and its connection with ICP-MS have been described previously [36]. The polyethylene tubing transfer line (6 mm i.d.)…”
Section: Apparatusmentioning
confidence: 99%
“…Details on the modification of the graphite furnace and its connection with ICP-MS have been described previously [36]. The polyethylene tubing transfer line (6 mm i.d.)…”
Section: Apparatusmentioning
confidence: 99%
“…The original silica windows (diameter of 2 cm) at the two ends of the graphite furnace were removed and replaced by two PTFE cylinders, and one of them was connected to the injector tube of the plasma torch, as has been detailed in previous work [12]. A polyethylene tubing transfer line with an i.d.…”
Section: Apparatusmentioning
confidence: 99%
“…The original silica windows at the two ends of the graphite furnace were removed and replaced with two PTFE cylinders, detailed in previous work (Li et al 2004). The original silica windows at the two ends of the graphite furnace were removed and replaced with two PTFE cylinders, detailed in previous work (Li et al 2004).…”
Section: Experimental Apparatus and Operating Conditionsmentioning
confidence: 99%
“…In temperature programme 2, the operating conditions were based on previous work performed in our laboratory (Li et al 2004, Zhang et al 2006). …”
Section: Optimisation Of Etv Parametersmentioning
confidence: 99%
See 1 more Smart Citation