1981
DOI: 10.1002/xrs.1300100310
|View full text |Cite
|
Sign up to set email alerts
|

Direct determination of trace elements in coal: Wavelength‐dispersive X‐ray spectrometry with matrix correction using compton scattered radiation

Abstract: An X-ray fluorescence method is described for the direct determination, without pretreatment, of up to 55 trace elements in coal and coal-derived materials. A single assay specimen is prepared by blending finely crushed sample with a binder and briquetting. Calibration is effected by a suite of synthetic calibration standards prepared from spectrographically pure materials blended into graphite. Variations in ash and sulphur content required matrix absorption corrections to analyte and background intensities, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
3
0

Year Published

1985
1985
2013
2013

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(4 citation statements)
references
References 16 publications
1
3
0
Order By: Relevance
“…Using the recommended instrumental procedure with a sequential spectrometer, including matrix absorption corrections for variations in ash yield and sulfur content, good results were obtained for three coal SRMs. 130 Results for Australian coals 134 showed that the ranges of values agreed well with those determined by other methods. 8 A thorough investigation of trace elements in South African coals has shown that "the quality of the data depends critically on the accuracy of the mass absorption coefficients and the accuracy with which the background and line overlap corrections can be calculated".…”
Section: Crc Critical Reviews In Analytical Chemistrysupporting
confidence: 72%
See 1 more Smart Citation
“…Using the recommended instrumental procedure with a sequential spectrometer, including matrix absorption corrections for variations in ash yield and sulfur content, good results were obtained for three coal SRMs. 130 Results for Australian coals 134 showed that the ranges of values agreed well with those determined by other methods. 8 A thorough investigation of trace elements in South African coals has shown that "the quality of the data depends critically on the accuracy of the mass absorption coefficients and the accuracy with which the background and line overlap corrections can be calculated".…”
Section: Crc Critical Reviews In Analytical Chemistrysupporting
confidence: 72%
“…J4 Refinements have extended XRF to cover about 55 trace elements in coal. 130 Again the ground coal (-75 pm) was mixed with a binder and 6 g of the mixture was briquetted. Due to the lack of suitable standard materials, several synthetic standards were prepared from spectrographically pure compounds and briquetting graphite.…”
Section: Crc Critical Reviews In Analytical Chemistrymentioning
confidence: 99%
“…It is known that printed circuit boards have various components with wide variations in concentration . Scattered X‐ray intensities are used as internal standards to correct matrix effects . Correction with scattered X‐ray intensities is based on the theory that the mass absorption coefficients of samples are inversely proportional to the intensities of scattered X‐ray, and the method is simple and reliable.…”
Section: Introductionmentioning
confidence: 99%
“…This is vital for their correct use in combustion systems. The determination of these parameters by means of a quick and nondestructive technique, such as measurement of the natural activity of gamma rays of the lignocellulosic briquettes (Alvarez and Dopíco, 1991) or dispersive X-ray fluorescence (Ayala et al, 1994;Míguez et al, 2002;Mills et al, 1981) is a topic of great interest. The reactivity of waste and biomass varies widely from one type of fuel to another.…”
mentioning
confidence: 99%