2019
DOI: 10.1103/physreva.100.052508
|View full text |Cite
|
Sign up to set email alerts
|

Direct determination of the energy of the first excited fine-structure level in Ba6+

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
13
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
3

Relationship

2
7

Authors

Journals

citations
Cited by 21 publications
(15 citation statements)
references
References 32 publications
1
13
0
Order By: Relevance
“…HCI clocks are expected to be a sensitive probe for time variations of the fine-structure constant α for testing modern physical theories beyond the Standard Model 15 . A number of candidates for HCI clocks have been proposed [16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31] , and their transition wavelengths have been experimentally investigated [32][33][34][35] . Micke et al recently demonstrated quantum logic spectroscopy of HCIs using Ar 13+ , which has no hyperfine structure, promising realization of the HCI clocks 36,37 .…”
mentioning
confidence: 99%
“…HCI clocks are expected to be a sensitive probe for time variations of the fine-structure constant α for testing modern physical theories beyond the Standard Model 15 . A number of candidates for HCI clocks have been proposed [16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31] , and their transition wavelengths have been experimentally investigated [32][33][34][35] . Micke et al recently demonstrated quantum logic spectroscopy of HCIs using Ar 13+ , which has no hyperfine structure, promising realization of the HCI clocks 36,37 .…”
mentioning
confidence: 99%
“…As discussed in previous studies [26,37,39,40,[55][56][57], the strong visible lines observed in Tokamak or EBIT plasma mostly come from the low-lying states of the targeted ions, since these states are largely populated. Thus, in this work we focus on the 30 energy levels belonging to the three lowest configurations 4𝑓 14 5𝑠 2 5𝑝 4 , 4𝑓 13 5𝑠 2 5𝑝 5 and 4𝑓 12 5𝑠 2 5𝑝 6 .…”
Section: Theoretical Calculationsmentioning
confidence: 62%
“…The total wavelength uncertainty of this observation and calibration scheme was approximately 2 pm, which was comparable to the uncertainty of the scheme that the measured lines were calibrated by the lines from the buffer gas observed by a similar resolution spectrograph [44,45], but larger than the uncertainty of the scheme that the calibration source was overlapped with the real image of the ion observed by a higher resolution spectrograph [42]. Compared to these two schemes, our scheme is more convenient and flexible.…”
Section: Measurement Uncertaintiesmentioning
confidence: 69%